Functional principle
By default, the electronic outside thumbturn of the Xesar cylinder is disengaged. The cam
remains disengaged upon operating the outside thumbturn and the outside thumbturn
turns without engaging with the cam.
Hold an authorised Xesar identification medium to the reader unit of the Xesar cylinder to
mechatronically engage the outside thumbturn for five seconds so the cam of the Xesar
cylinder engages when operating the outside thumbturn.
The purely mechanically operated inside of versions with one-sided, electronic authorisa-
tion always remains engaged on Xesar cylinders and can be operated at any time.
On Xesar cylinders with double-sided, electronic authorisation the inside thumbturn oper-
ates identically to the electronic outside thumbturn.
Xesar cylinders feature an event memory for the last 1,000 events. Once the event memory
is full, the system overwrites the oldest entries with the most recent events. For this rea-
son, it is important to regularly synchronise events to prevent event records from being
lost.
Please refer to the corresponding data sheet for additional specifications at:
Note:
FZG and FAP versions do not feature a rotary damper for technical reasons.
Caution:
Please note the office mode function (Section:
identification media) and the
different acoustic and visual signals (Section:
)
Caution:
Xesar cylinders feature a rotary damper as standard. Ensure it is installed in its cor-
rect position (see assembly manual) as malfunctions would otherwise occur during
on-going operation. Malfunctions in unapproved installation positions do not repre-
sent product faults and are consequently not deemed as a valid reason for com-
plaints.
Caution:
Please note the following, important notices before use!