Before completing the installation, use a Construction Card to verify the correct function of the
wall reader and control unit when the door is open.
After having installed the wall reader and control unit, note that you can only operate the system
using a Construction Card until parameters have been completely configured.
Information on operation
Please note that the wall reader function can be safeguarded exclusively in conjunction with the
matching control unit. Wall readers and control units are exclusively intended to actuate electronic
locking components and technical equipment. EVVA shall assume no liability or accept warranty
claims for the correct function of the actuated devices themselves.
Instruct users of the electronic locking system to always keep identification media safe.
In the event that Xesar identification media is lost, it must be immediately blocked using the soft-
ware. The Xesar wall readers must be immediately updated using the Xesar tablet.
Please note that wall readers must be removed using the dedicated special tools only. Damage
caused by other tools shall render any liability, warranty or potentially separate guarantee claims
void.
Do not cover the reader equipment of the wall reader with metal materials.
Regularly check the correct condition and function of the wall reader and control unit (at mini-
mum once a month) as part of a functional check using authorised identification media.
We recommend you keep the locking system up-to-date by regularly installing software and firm-
ware updates. Make sure to run firmware updates when the door is open and run a functional test
after having completed the update.
Cleaning information
Use a soft, lint-free cloth and soapy water to clean any visible areas of the wall reader. Do not use
corrosive products or sprays that may be aggressive on glass surfaces, plastics or sealants and
seals.
Note the following, important notices regarding the use of Xesar control units.
Important notice
You must comply with the following warnings and information from EVVA Sicherheitstechnologie
GmbH (hereinafter referred to as "EVVA") if you install, programme and use the control unit. Keep
the instructions in the vicinity of the control unit.
Carefully read the Xesar system manual before commissioning your Xesar locking system. It is
available at