Check the lock for damage and dirt before assembling/installing the handle. Please also observe
the instructions of the lock manufacturer prior to assembly/installation. EVVA recommends using
correctly operating mortise locks to safeguard the handle operates correctly.
Exclusively use accessories and spare parts recommended by EVVA.
Please observe the corresponding international and national specifications in the corresponding
legislation, directives, standards and guidelines, particularly regarding the requirements for escape
routes and emergency exits, during project management and installation of the handles.
Note that changing over the handle from one side to the other must be performed in accordance
with the specifications in the assembly manual and exclusively when the battery has been re-
moved.
Please note that if you would like to install the handle in smoke control/fire doors, you must verify
the handles' suitability and potentially also obtain approval from the door manufacturer. The client
shall be responsible for this.
A certificate in compliance with EN 179 or EN 1125 from the lock manufacturer is crucial for use
of the handle in escape or panic doors. Check the correct function of the complete panic unit,
consisting of panic lock and handle fittings. The aforementioned certificate must confirm the
handles' suitability for installation.
An excessive tightening torque when fastening the fixing screws may cause handle malfunctions or
make it hard to operate the handle. For this reason, note the data in the assembly manual.
Before completing the installation, use a Construction Card to verify the correct function of the
handle when the door is open as per the specifications in the assembly manual.
After having installed the handle, please note that you can only operate the system using a Con-
struction Card until parameters have been completely configured.
Information on operation
Instruct users of the electronic locking system to always keep identification media safe.
In the event that Xesar identification media is lost, it must be immediately blocked using the soft-
ware. The mechatronic lock cylinder must be immediately updated.
Do not carry or lift the door panel using the handle.
Do not cover the reader equipment of the handle with metal materials.
Regularly check the correct condition and function of the handle (at minimum once a month) as
part of a functional check using authorised identification media.
We recommend you keep the locking system up-to-date by regularly installing software and firm-
ware updates. Make sure to run firmware updates when the door is open and run a functional test
after having completed the update.
Summary of Contents for Xesar 2.0