Please note that the corresponding IP rating of lock cylinders with elongated outside turn sleeves
can only be safeguarded if the elongated outside turn sleeve protrudes from the protective es-
cutcheon by a maximum of 3 mm.
Information on operation
Instruct users of the electronic locking system to always keep identification media safe.
In the event that Xesar identification media is lost, it must be immediately blocked using the soft-
ware. The corresponding lock cylinder must be immediately updated using the Xesar tablet.
Please note that a door is not automatically locked after having closed it. Doors must be locked
manually by turning the thumbturn. In the event that it is not possible to remove the thumbturn,
attempt to set the lock cylinder to office mode and then remove it as usual it using the assembly
tool. In the event that this fails, you additionally have the option of blocking the thumbturn sleeve
using a slim metal pin via a small hole on the front of the electronics module and be able to con-
sequently remove the thumbturn using the assembly tool.
The thumbturn is not intended as an object to move the door panel (as would be the knob, han-
dle, etc.). Do not carry or lift the door panel using the thumbturn.
Do not stand on the thumbturn.
Do not cover the reader equipment of the lock cylinder with metal materials.
Regularly check the correct condition and function of the lock cylinder (at minimum once a
month) as part of a functional check using authorised identification media.
We recommend you keep the locking system up-to-date
by regularly installing software and firmware updates. Make sure to run firmware updates when
the door is open and run a functional test after having completed the update.
Note:
Depending on the cylinder's protrusion beyond the escutcheon or any installed
cylinder rosettes, the Xesar thumbturn may be hard to operate as a result of friction
caused by the seal on the escutcheon or rosette of the cylinder. There is the option
to remove said seals when installing indoors.