40
Xe
sar
Sy
st
em
manu
al
2
.0
f
or
v
er
si
on
2
.0
.3
6.1
7
| 2
4.
06
.2
01
5
| mi
spr
int
ing
and
te
chni
cal
c
hange
s
re
se
rv
ed
Information regarding installation and the correct installation situation
Exclusively specialist personnel must install escutcheons according to the specifications in the as-
sembly manual enclosed with the product. EVVA shall assume no liability for any kind for damage
resulting from improper assembly/installation.
Please note that the maximum nut correction position of the mortise lock must be 2° to ensure
the Xesar escutcheon operates correctly, as otherwise malfunctions cannot be excluded.
Check the lock for damage and dirt before assembling/installing the escutcheon. Please also ob-
serve the instructions of the lock manufacturer prior to installation of the escutcheon.
EVVA recommends using correctly operating mortise locks to safeguard the escutcheon operates
correctly.
Observe the corresponding international and national specifications in the corresponding legisla-
tion, directives, standards and guidelines, particularly regarding the requirements for escape routes
and emergency exits, during project management and installation of the escutcheons.
Note that you must choose the correct cylinder length depending on the door panel thickness
when installing mechanical lock cylinders. In installation situations or applications that are critical
to security the lock cylinder must protrude from the protective escutcheon by a maximum of 3
mm.
Before installing escutcheons – in particular in metal frame doors – check the installation situation
to prevent injuries (e.g. squashed limbs). In these cases, we recommend using a handle suitable for
metal frame doors.
Please note that if you install the escutcheon in smoke control/fire doors, you must verify the
components' suitability and potentially also obtain approval from the door manufacturer. The cli-
ent shall be responsible for this.
A certificate in compliance with EN 179 or EN 1125 from the lock manufacturer is crucial for use
of the escutcheon in escape or panic doors. Check the correct function of the complete panic unit,
consisting of escutcheon, panic lock and panic bar. The aforementioned certificate must confirm
the escutcheons' suitability for installation.
An excessive tightening torque when fastening the fixing screws may cause escutcheon malfunc-
tions or make it hard to operate the escutcheon. For this reason, note the data in the assembly
manual.
Before completing the installation, use a Construction Card to verify the correct function of the
escutcheon when the door is open as per the specifications in the assembly manual.
After having installed the escutcheon, note that you can only operate the system using a Con-
struction Card until parameters have been completely configured.
Note that in the event of a clearance within the cylinder area of the door panel you are required
to seal the area using a conventional, mechanical cylinder, a blind cylinder or fire protection lami-
nate. EVVA explicitly declares that this is the only method to maintain the validity of the fire pro-
tection certificate for the escutcheon.