Wave Analyzer Medica 700 User Guide
66
Overview of the Software
No
Column
2
IPO mm/Hg
Displays the actual intraocular pressure that was measured.
3
Pachy
Displays the thickness of the cornea at its center, in microns.
4
IPOc mm/Hg
Displays corrected values for the intraocular pressure, taking the pachymeter
readings into account.
5
ACD
Displays the anterior chamber depth
6
ACV
Displays the anterior chamber volume.
7
Kappa Angle
Displays the kappa angle.
8
Decentration
Displays the decentration between the pupil apex and the visual point on the cornea.
9
IC Angles
Displays the interior chamber angles for each eye.
Warning: The safety and efficacy of the Wave Analyzer Medica 700 in measuring
intraocular pressures in patients with greater than 3 diopters of corneal astigmatism or
greater than 33mmHg of intraocular pressure has not been evaluated.”
4. 7 ACA
This tab includes data on the Anterior Chamber of the Cornea
Anterior Chamber Analysis
The
Anterior Chamber Analyses
sub-tab of the
Cornea
tab displays diagram and graph for
the anterior chamber analysis (pachymetry, irido corneal angle, corneal thickness). The user
can edit this diagram by re-positioning the measured points.
Note:
it is only possible to save
the reposition of the points immediately after the measurements. When retrieving results,
points that are repositioned will not be saved.
Summary of Contents for Medica 700
Page 2: ......
Page 7: ...1 Introduction I...
Page 11: ...2 Safety II...
Page 15: ...3 Equipment and Installation III...
Page 25: ...4 Overview of the Software IV...
Page 38: ...Wave Analyzer Medica 700 User Guide 32 Overview of the Software Ringer Screen...
Page 94: ...5 Managing Patients V...
Page 103: ...6 Performing a Diagnostic VI...
Page 128: ...7 Managing the List of Test Results VII...
Page 135: ...8 Managing the Database VIII...
Page 141: ...9 General Actions and Features IX...
Page 147: ...10 Configuring the Unit X...
Page 189: ...11 What Should I Do If XI...
Page 191: ...12 Maintenance XII...
Page 195: ...189 Wave Analyzer Medica 700 User Guide 189 Maintenance 4 Head and ChinRest are lowered 5...
Page 196: ...Wave Analyzer Medica 700 User Guide 190 Maintenance 6 7...
Page 197: ...191 Wave Analyzer Medica 700 User Guide 191 Maintenance 8 9...
Page 198: ...Wave Analyzer Medica 700 User Guide 192 Maintenance 10 11...
Page 199: ...193 Wave Analyzer Medica 700 User Guide 193 Maintenance 12...
Page 200: ...Wave Analyzer Medica 700 User Guide 194 Maintenance 13...
Page 201: ...195 Wave Analyzer Medica 700 User Guide 195 Maintenance 14...
Page 202: ...Wave Analyzer Medica 700 User Guide 196 Maintenance 15...
Page 203: ...197 Wave Analyzer Medica 700 User Guide 197 Maintenance 16...
Page 204: ...13 Appendices XIII...