Setup & Operation 14. I/O Remote Settings
VT Rev.1
99
14. I/O Remote Settings
This section describes the functions and timings of input and output signals.
The remote functions may be assigned to your standard I/O board(s), or fieldbus I/O
board(s) to enhance robot system control - either from an operational unit of your choice
or a sequencer.
Remote function is initially assigned to both input and output from 0 to 7.
To accept external remote inputs, assign the remote function and the control device is
remote. For further details, refer to the section,
Remote Control Software Configuration
in
EPSON RC+ 7.0 User’s Guide - Remote Control
.
The user defines the I/O number that a remote function is assigned to using software
configuration. For further details, refer to the section,
Remote Control Software
Configuration
in
EPSON RC+ 7.0 User’s Guide - Remote Control
.
For details about I/O cable connection, refer to sections on
Setup & Operation 13:
Standard I/O Connector
and
17. Fieldbus I/O
.
For details about communication with external equipment, refer to
EPSON RC+ 7.0
User’s Guide -12. Remote Control
.
CAUTION
When using remote I/O, always make sure of the following. Using the robot
system under unsatisfactory conditions may cause malfunction of the system
and/or safety problems.
-
Assign remote functions to inputs/outputs correctly and wire correctly when
setting up remote I/O signals.
-
Make sure that the functions correspond to the correct input/output signals
before turning ON the system.
When verifying the robot system operation, prepare for failures with initial
settings or wiring. If the Manipulator functions unusually by the failures with
initial settings or wiring, press the Emergency Stop switch immediately to stop
the Manipulator.
-
Remote function is available when virtual I/O is enabled.
-
When you set up a remote I/O signal, please either keep a written record of the settings
or store the data in a file for later reference.
-
When you set up a fieldbus I/O signal to the remote function, response depends on the
baud rate of the fieldbus. For details of fieldbus response, refer to the following manual.
Robot Controller RC700 / RC90 Option Fieldbus I/O.
NOTE
Summary of Contents for VT Series
Page 1: ...6 Axis Robots VT series MANIPULATOR MANUAL Rev 1 EM18YR3817F ...
Page 2: ...MANIPULATOR MANUAL VT series Rev 1 ...
Page 8: ...vi VT Rev 1 ...
Page 16: ...TABLE OF CONTENTS xiv VT Rev 1 ...
Page 18: ......
Page 31: ...Setup Operation 2 Specifications VT Rev 1 15 2 4 Outer Dimensions ...
Page 32: ...Setup Operation 2 Specifications 16 VT Rev 1 Unit mm ...
Page 33: ...Setup Operation 2 Specifications VT Rev 1 17 2 5 Standard Motion Range Unit mm ...
Page 130: ......
Page 138: ...Maintenance 3 Manipulator Structure 122 VT Rev 1 3 Manipulator Structure ...