Maintenance 5. Backup and Restore
130
VT Rev.1
5.4 Restore
Restore the Manipulator status from EPSON RC+ 7.0.
CAUTION
■
Make sure that the data used for restore was saved previously for same
Manipulator.
■
Do not edit the backup files. Otherwise, operation of the robot system after
data restoration to the Manipulator is not assured.
(1)
Select the EPSON RC+ 7.0 menu-[Tools]-[Controller] to display the [Controller Tools]
dialog.
(2)
Click the <Restore Controller…> button to display the [Browse For Folder] dialog.
(3)
Specify the folder that contains the backup data. Backup data folders are named
using the following format:
B_VT_ serial number_ date status was saved
→
Example: B_VT_12345_2016-04-03_092941
Controller status backup to USB memory function can also be specified for restore.
Specify the following folder.
NOTE