Setup & Operation 3. Environments and Installation
26
VT Rev.1
3.3 Mounting Dimensions
Mounting Area
Be sure to have the following space available in addition to the space for mounting the
Manipulator and peripheral equipment.
Space for teaching points
Space for maintenance and inspections
(Ensure a space to open the covers and plates for maintenance.)
Space for cables
The minimum bend radius of the power cable is 90 mm. When installing the cable, be
sure to maintain sufficient distance from obstacles. In addition, leave enough space for
other cables so that they are not bent forcibly.
Ensure distance to the safeguard from the maximum motion range is more than 100 mm.
[Unit: mm]