Disassembly and Assembly
3.
4.
5.
6.
Release the 3 hooks securing the RF motor gear cover to the front/rear tractor
select lever assembly and remove the cover.
Ribbon Feed
Drive Gear
Ribbon Feed
Figure 3-31. Removing the Tractor Select Lever 1
On the connector junction board assembly, disconnect the white, 6-pin
connector for RF motor control and the yellow, 2-pin connector for the tractor
select sensor.
Remove the CPN (M3 x 6) screw securing the front/rear tractor select lever
assembly to the left side frame.
Remove the RF motor drive gear from the front/rear tractor select lever
assembly. Then remove the lever assembly from the left side frame.
EPSON
Service Manual
3-29
Summary of Contents for DFX-5000+
Page 1: ...EPSON Service Manual Epson America Inc TM DFX5K ...
Page 154: ......
Page 212: ...Appendix Table A S CN7 C117 MAIN Board Assembly A 8 EPSON DFX 5000 Service Manual ...
Page 218: ......
Page 219: ...Appendix DFX 5000 Exploded Diagram 1 EPSON DFX 5000 Service Manual A 15 ...
Page 220: ...Appendix Figure A 5 Exploded Diagram 2 A 16 EPSON DFX 5000 Service Manual ...
Page 221: ...597 J86 ...
Page 222: ...Appendix A 18 EPSON DFX 5000 Service Manual ...
Page 223: ...Appendix Figure A 7 C117 MAIN Board Circuit Diagram EPSON DFX 5000 Service Manual A 19 ...