Disassembly and Assembly
Removing the PG Sensor and PG Motor
CAUTION
When you remove or install the PG sensor, be careful not to bend the PG motor detection
board.
1.
Remove the connector junction board assembly. (Refer to the previous page.)
2.
Remove the CPS (P) (M3 x 6) screw securing the PG sensor. Then pull the PG
sensor forward and remove it.
3.
Remove the 2 CP (PS) (M3 x 6) screws securing the PG motor and remove the
motor.
CP
Platen Gap
Pinion
Figure 3-36. Removing the PG Sensor and PG Motor
Assembly Notes
When you install the PG motor, be sure the backlash between the PG motor and motor
transmission
is between 0.05 and 0.15 mm (almost no backlash).
When you install the PG sensor, join portion A in Figure 3-36 correctly and match the
screw at portion B to
hole, so that the PG sensor is secure.
Adjustment Required
When you install the PG sensor or PG motor, perform theplaten
motor value (platen
adjustment, us described in Chapter 4.