Adjustments
8.
If the distance measured at the left side is greater than that measured at the
right side, move the parallelism adjust lever in the direction shown by the
white arrow in Figure 4-7.
distance measured at the left side is less than
that measured at the right side, move the lever in the direction shown by the
black arrow.
Note :
The carriage guide shaft moves as shown in Figure 4-7. For example, when
the parallelism adjust lever is moved in the direction of the black arrow, the
distance between the right side of the platen and printhead nose narrows a
little bit.
9. Repeat steps 7 and 8 until the difference between the distances measured at
the two positions is less than 0.01 mm. (The
dial gauge matches the
notches.)
10. When the difference is within the specified range, tighten the 2 screws
securing the parallelism adjust lever. Then measure the distances again, as
described in step 5.
11. If the difference between the measured distances is within the specified range,
apply screw lock to the 2 screws. (See Chapter 6 for lubrication and adhesive
application instructions.)
EPSON
Service Manual
4-9
Summary of Contents for DFX-5000+
Page 1: ...EPSON Service Manual Epson America Inc TM DFX5K ...
Page 154: ......
Page 212: ...Appendix Table A S CN7 C117 MAIN Board Assembly A 8 EPSON DFX 5000 Service Manual ...
Page 218: ......
Page 219: ...Appendix DFX 5000 Exploded Diagram 1 EPSON DFX 5000 Service Manual A 15 ...
Page 220: ...Appendix Figure A 5 Exploded Diagram 2 A 16 EPSON DFX 5000 Service Manual ...
Page 221: ...597 J86 ...
Page 222: ...Appendix A 18 EPSON DFX 5000 Service Manual ...
Page 223: ...Appendix Figure A 7 C117 MAIN Board Circuit Diagram EPSON DFX 5000 Service Manual A 19 ...