Adjustments
Figure 4-6. Dial Gauges and Dial Gauge Base Attachment
7 . U s i n g t h e l e f t d i a l g a u g e , m e a s u r e t h e d i s t a n c e b e t w e e n t h e p l a t e n a n d
carriage guide shaft on the left side. Then measure the distance between the
platen and carriage guide shaft on the right side, and compare the values.
(Figure 4-7 shows the measurement position and the parallelism adjust lever
operation
Note :
When you shift the carriage manually, do not touch either dial gauge. Rotate
the carriage motor pulley.
Figure 4-7. Carriage Guide Shaft Parallelism Adjustment
4-8
EPSON