Troubleshooting
Level 2 FIP
3-228
12
PWB Drive (PL15.1.15) continuity
1. Disconnect the P/J60 connector from the PWB Drive.
2. Measure the voltage between J60-1 <=> J60-2.
Is there 24V DC between J60-1 <=> J60-2?
Replace the PWB Drive.
(Refer to Ch4-4.2.18.5)
Go to step 13.
13
Harness Assy 24V (PL15.2.6) continuity
1. Disconnect the P/J163 connector from the LVPS (PL15.1.10).
2. Measure the voltage between P163-1 <=> P163-2.
Is there 24V DC between P163-1 <=> P163-2?
Replace the Harness Assy 24V
(PL15.2.6).
Step
Check
Treatment
Yes
No
Summary of Contents for AcuLaser C3000 Series
Page 20: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 71: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 118: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 318: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 472: ...C H A P T E R 5 ADJUSTMENT ...
Page 477: ...C H A P T E R 6 MAINTENANCE ...
Page 491: ...C H A P T E R 7 AcuLaserC4100 ...
Page 548: ......
Page 549: ......
Page 550: ......
Page 551: ......
Page 552: ......
Page 553: ......
Page 554: ......
Page 555: ...C H A P T E R 8 AcuLaserC3000 ...
Page 579: ...Model AcuLaser C3000 Board C569MAIN BOARD Sheet 1 of 5 Rev B ...
Page 580: ...Model AcuLaser C3000 Board C569MAIN BOARD Sheet 2 of 5 Rev B ...
Page 581: ...Model AcuLaser C3000 Board C569MAIN BOARD Sheet 3 of 5 Rev B ...
Page 582: ...Model AcuLaser C3000 Board C569MAIN BOARD Sheet 4 of 5 Rev B ...
Page 583: ...Model AcuLaser C3000 Board C569MAIN BOARD Sheet 5 of 5 Rev B ...
Page 584: ...C H A P T E R 9 APPENDIX ...
Page 674: ......
Page 675: ......
Page 676: ......
Page 677: ......
Page 678: ......
Page 679: ......
Page 680: ......