Security Configuration Command Set
Configuring Convergence End Points (CEP) Phone Detection
Matrix NSA Series Configuration Guide
14-113
14.3.8.11 set cep detection-id protocol
Use this command to specify an IP protocol type for H.323, Siemens, or SIP convergence end points
detection. If an IP address is not set for a phone detection group as described in
Section 14.3.8.10
,
this will configure detection on UDP and/or TCP ports using a port range defined with the
set cep
detection-id porthigh
|
portlow
command as described in
Section 14.3.8.12
.
set cep detection-id id protocol
{
tcp
| udp | both | none
}
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to enable both TCP and UDP convergence end points detection for CEP
detection group 1
:
NOTE:
This command applies only to Siemens, H.323, and SIP phone detection. Cisco
detection uses CiscoDP as its discovery method.
id
Specifies a CEP configuration group ID. This group must
be created and enabled using the
set cep detection-id
command as described in
Section 14.3.8.8
. Valid values are
1
-
2147483647
.
tcp
| udp | both |
none
Sets the CEP IP protocol type to be used for detection as:
•
TCP
•
UDP
•
Both UDP and TCP
•
None
Matrix>
set cep detection-id 1 protocol both