ENCAD T-200 and T-200+ Service Manual
Maintenance
3-37
To perform the Color Deadband Alignments
Depress the “Menu” key on the control panel to begin the main
menu subroutine.
Using the “Up Arrow”, Down Arrow” and “Select” keys on the
control panel select:
Utility Menu
Db Calib
Color Db Test
Select “Color Db Test” to run the color deadband test.
The test consists of 12 default calibration settings. When the test is
run it will print out a pattern of 5 calibration lines for each of
the 12 settings. It will print this pattern in black first, followed
by cyan, magenta and then yellow. Also printed will be the
current settings for each of the four colors as well as the slow
deadband setting.
When the plot is complete, select “K Fast DB=
XX
”.
Observe the plot and using either “Up Arrow” or “Down Arrow”,
rotate through the selections until one that seems closest to the
correct value is selected. Press “Select” to accept the selection.
Continue performing these steps until the all color deadband
adjustments are correct.
Summary of Contents for T-200
Page 1: ...SERVICE MANUAL ...
Page 2: ...T 200 AND T 200 COLOR INKJET PRINTER PLOTTERS SERVICE MANUAL Part Number 219863 00 ...
Page 152: ...ENCAD T 200 and T200 Service Manual Parts List 6 3 Figure 6 1 Left Side Parts Breakdown ...
Page 156: ...ENCAD T 200 and T200 Service Manual Parts List 6 7 Figure 6 3 Right Side Parts Breakdown ...
Page 158: ...ENCAD T 200 and T200 Service Manual Parts List 6 9 Figure 6 4 Inner Platen Parts Breakdown ...