ENCAD T-200 and T-200+ Service Manual
Maintenance
3-21
SPIN HEAD ON
MICROMETER GAUGE
TO FACE BACKWARDS
TIGHTEN SET
SCREWS
ENSURE TIP EXTENDS
BELOW CARTRIDGE
1/4" (6mm)
MICROMETER
DIAL GAUGE
TEST CARTRIDGE
MEASURING
TIP EXTENDER
Figure 3-14. Setting Up Tools from Height Gauge Kit.
3. Place the test cartridge upright on a flat surface and ‘zero’ the
gauge by loosening the knob near the top and turning the dial
until the needle is at the ‘0’ position on the dial. Tighten the
knob. See Figure 3-15.
ZERO
GAUGE
ENSURE PRESSURE IS
PLACED ON THE REAR
OF THE CARTRIDGE
0
Figure 3-15. Zeroing the Micrometer Gauge.