Theory of Operation
2-17
ENCAD T-200 and T-200+ Service Manual
Power Supply
An internal UL recognized switching power module supplies power for
the printers. It provides a constant 24VDC output from input voltage in
the 90-132 VAC and 180-246 VAC ranges. A power switch turns the
power on and off. The 24VDC is applied to the MPWA where it is
further regulated and separated into 24VDC, 13VDC, and 5VDC. The
24V supply is used for: the stepper controller (which advances the
paper); the servo controller (which moves the Carriage); and power to
fire the inkjets. The 5V supply powers the logic circuits.
The power supply is fused using a 6.3A 250V fast blow type fuse.
The outputs share a common ground which is isolated from earth
ground with in the supply itself. Earth ground and DC ground are
connected external of the power supply.
The power supply will shut down under overload/short circuit conditions
on any output over the full range of input voltage. Overvoltage protec-
tion is 20%-30% above nominal for the 24V output.
Beeper and Fans
The beeper contains built-in driver circuitry so that it beeps under
firmware control. The beeper alerts the user to error conditions.
A fan is located inside the platen with its fan vent seen from under the
platen on the right side of the printer. This fan provides suction on the
platen bed and holds the paper (media) flat during the printing process.
It also serves to cool the power supply since the power supply is located
inside the platen.
Summary of Contents for T-200
Page 1: ...SERVICE MANUAL ...
Page 2: ...T 200 AND T 200 COLOR INKJET PRINTER PLOTTERS SERVICE MANUAL Part Number 219863 00 ...
Page 152: ...ENCAD T 200 and T200 Service Manual Parts List 6 3 Figure 6 1 Left Side Parts Breakdown ...
Page 156: ...ENCAD T 200 and T200 Service Manual Parts List 6 7 Figure 6 3 Right Side Parts Breakdown ...
Page 158: ...ENCAD T 200 and T200 Service Manual Parts List 6 9 Figure 6 4 Inner Platen Parts Breakdown ...