2. Product Information
EM15 User’s Manual
6
2.2 Technical Specifications
Input
&O
utput
⚫
Input Voltage:
220V/380V/480V/575V/660V±15%
⚫
Input Frequency:
47~63Hz
⚫
Input Frequency Resolution:
0.01Hz (Digital setting); maximum frequency×0.025% (Analog setting)
⚫
Output Voltage:
0~Rated input voltage
⚫
Output Frequency:
0~320Hz(SFC); 0~3200Hz (V/F)
T
ec
hn
ica
l P
er
fo
rma
nce
⚫
Control Mode:
Sensor-less vector control(SVC); Closed-loop vector control (FVC); Voltage/Frequency
(V/F) control
⚫
Carrier Frequency:
0.5kHz~16kHz
⚫
Startup Torque:
G type: 0.5Hz/150% (FVC); 0Hz/180%(FVC); P type: 0.5Hz/100%
⚫
Speed Range:
1:100(SVC);1:1000(FVC)
⚫
Speed Stability Accuracy:
±0.5%(SVC);±0.02%(FVC)
⚫
Torque Control Accuracy:
±5%(FVC)
⚫
Overload Capacity:
G type:150% rated current 60s; 180% rated current 3s; P type: 120% rated current
60s;150% rated current 3s.
⚫
Torque Boost:
Auto boost; Manual boost 0.1%~30.0%
⚫
DC braking:
0.00Hz~maximum frequency (DC braking frequency); 0.0s~36.0s(Braking time);
0.0%~100.0%( Braking trigger current value)
Indi
vi
dual
ized
Fu
nct
ions
⚫
Built-in Simple PLC / Multiple Speeds:
It realizes up to 16 speeds via the simple PLC function or
combination of DI terminal states.
⚫
Built-in PID:
It realizes closed loop control system easily.
⚫
Auto voltage regulation (AVR):
It can keep constant output voltage automatically when the mains
voltage fluctuation
⚫
Overvoltage/ Overcurrent Stall Control:
The current and voltage are limited automatically during the
running process so as to avoid frequently tripping due to overvoltage / over current.
⚫
Rapid Current Limit:
To avoid frequently over current faults of the frequency inverter.
⚫
Torque Limit and Control:
It can limit the torque automatically and prevent frequently over current
tripping during the running process. Torque control can be implemented in the VC mode.
⚫
High Performance:
Control of asynchronous motor is implemented through the high-performance current
vector control technology.
⚫
Virtual I/O:
Five groups of virtual DI/DO can realize simple logic control.
⚫
Timing Control:
Time range: 0.0~6500.0 minutes
⚫
Motor Overheat Protection:
The optional I/O extension card enables AI3 to receive the motor
temperature sensor input (PT100, PT1000) so as to realize motor overheat protection.
⚫
Multiple Encoder Types:
It supports differential encoder, open-collector encoder
⚫
Protection Mode:
Motor short-circuit detection after power-on, input/output phase loss protection, over
current and overvoltage protection, less voltage protection, overheat protection and overload protection,etc
E
xt
ern
al
Int
erf
ace
⚫
Running Command Giving:
key panel; Control terminals; Serial communication port; You can switch
between these giving in various ways.
⚫
Frequency Giving:
There are 10 kinds frequency giving: digital setting, analog voltage setting, analog
current setting, pulse setting and serial communication port setting.
⚫
Programmable Digital Input:
6 digital input (DI) terminals, one of which supports up to 100 kHz
high-speed pulse input
⚫
Programmable Analog Input:
3 analog input (AI) terminals, AI1,AI2 support 0V~10 V or 0mA~20mA
input, AI3 support -10V~+10V
⚫
Programmable Open Collector Output:
1 FMP output terminal, that supports 0–100 kHz square wave
signal output (Can be used as DO output)
⚫
Programmable Analog Output:
2 analog output (AO) terminals, both of them supports 0mA~20mA
current output and 0V~10V voltage output.
⚫
Relay Output:
2 relay output terminal (2.2KW and below only have 1 relay output terminal)
E
nvi
ronme
nt
⚫
Installation Location:
Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour,
drip or salt.
⚫
Altitude:
Lower than 1000m
⚫
Ambient Temperature:
-10°C~ +40°C (de-rated if the ambient temperature is between 40°C and 50°C)
⚫
Humidity:
Less than 95%RH, without condensing
⚫
Vibration:
Less than 5.9 m/s2 (0.6 g)
⚫
Storage Temperature:
-20°C ~ +60°C