Appendix II
EM15 User’s Manual
152
Code
Parameter Name
Functional description
Default
Property
d2-00 V/F curve setting
0: Linear V/F
1: Multi-point V/F
2: Square V/F
3: 1.2-power V/F
4: 1.4-power V/F
6: 1.6-power V/F
8: 1.8-power V/F
10: V/F complete separation
11: V/F half separation
0
★
d2-01 Torque boost
0.0% ( torque auto-boost)
0.1%~30.0%
Model
dependent
★
d2-02
Cut-off frequency of
torque boost
0.0%~80.0%
Actual
cut-off
frequency=
Motor
rated
frequency*(d2-02)
50.0%
★
d2-03
Multi-point V/F frequency
1 (F1)
0.00 Hz ~ d2-05
0.00 Hz
☆
d2-04
Multi-point V/F voltage 1
(V1)
0.0%~100.0%
0.0%
☆
d2-05
Multi-point V/F frequency
2 (F2)
d2-03 to d2-07
0.00 Hz
☆
d2-06
Multi-point V/F voltage 2
(V2)
0.0%~100.0%
0.0%
☆
d2-07
Multi-point V/F frequency
3 (F3)
d2-05 ~ maximum frequency
0.00 Hz
☆
d2-08
Multi-point V/F voltage 3
(V3)
0.0%~100.0%
0.0%
☆
d2-09
V/F slip compensation
coefficient
0.0%~200.0%
0.0%
☆
d2-11
V/F oscillation
suppression gain
0~100
40
☆
d2-13 V/F curve setting
0: Digital setting (d2-14)
1: AI1
2: AI2
3: AI3
4: Pulse setting (HDI)
5: Multi-function
6: Simple PLC
7: PID
8: Communication setting
(Note: 100.0% corresponds to the rated motor voltage)
0
☆
d2-14
Voltage digital setting for
V/F separation
0 V ~ rated motor voltage
0 V
☆
d2-15
Voltage rise time of V/F
separation
0.0s~1000.0s
Note: It indicates the time for the voltage rising from 0
V ~ rated motor voltage.
0.0s
☆