Appendix I
EM15 User’s Manual
122
{
crc_value=crc_value>>1;
}
}
}
return(crc_value);
}
Definition of communication parameter address
Read and write function-code parameters (Some functional code is not changed, only for the manufacturer use.)
The group number and mark of function code is the parameter address for indicating the rules.
High level bytes: Group A0~AF(GroupA0-A2/ Groupb0-bC), Groupb0-bF(Group C0-C6/Groupd0-d6),
70-7F(Group U)
Low level bytes: 00 to FF
For example: b0-03, address indicates to 0xA303.
Note:
Group U: Only for reading parameter, cannot be changed parameters, some parameters cannot be changed
during operation, some parameters regardless of what kind of state the inverter in, the parameters cannot be
changed. Change the function code parameters, pay attention to the scope of the parameters, units, and relative
instructions.
Function code group
Communication inquiry address
Inquiry address When
Communication modifies RAM
A0~ A2
0xA000~ 0xA2FF
0x4000~ 0x42FF
b0~bC
0xA300~ 0xAFFF
0x4300~ 0x4FFF
C0~C6
0xb000~ 0xB7FF
0x5000~ 0x57FF
d0~d6
0xB800~ 0xBEFF
0x5800~ 0x5EFF
U0
0x7000~ 0x70FF
Besides, due to EEPROM be frequently stored, it will reduce the lifetime of EEPROM. In the communication
mode, and some function codes don’t have to be stored as long as change the RAM value.
Stop/start parameter
Parameter
address
Parameter description
Parameter
address
Parameter description
1000
Communication set value
(-10000 ~ 10000)(Decimal)
1010
PID setting
1001
Running frequency
1011
PID feedback
1002
DC Bus voltage
1012
PLC process
1003
Output voltage
1013
Pulse input frequency, unit: 0.01KHz
1004
Output current
1014
Feedback speed, unit:0.1Hz
1005
Output power
1015
Remaining running time
1006
Output torque
1016
Voltage before AI1correction
1007
Running speed
1017
Voltage before AI2correction
1008
DI input terminal
1018
Voltage before AI3correction
1009
DO output terminal
1019
Linear speed
100A
AI1 voltage
101A
Present power-on time
100B
AI2 voltage
101B
Present running time
100C
AI3 voltage
101C
Pulse input frequency, unit:1Hz
100D
Counting value input
101D
Communication setting value
100E
Length value input
101E
Actual feedback speed