Appendix II
EM15 User’s Manual
136
Code
Parameter Name
Functional description
Default
Property
b5-45
AI lower than minimum
input setting selection
Unit’s digit:AI1 lower than minimum input setting
0:corresponding minimum input setting
1:0.0%
Ten’s digit:AI2 lower than minimum input setting
selection, same as above
Hundred’s digit:AI3 lower than minimum input
setting selection, same as above
H.000
☆
Group b6: Pulse/Analog Output Terminals
b6-00 FMP function selection
0: Running frequency corresponding to 0~Max.
operation frequency
1: Set frequency corresponding to 0~Max. operation
frequency
2: Output current corresponding to 0~Doubled motor
rated current
3: Output torque (absolute value) corresponding to
0~double rated torque
4: Output power corresponding to 0~Doubled motor
rated power
5: Output voltage corresponding to 0~1.2 times DC bus
voltage
6: Pulse input corresponding to 0Hz~100kHz
7: AI1 corresponding to 0~10V
8: AI2 corresponding to 0~10V
9: AI3 corresponding to 0~10V
12: Communication setting corresponding to 0~32767
13: Motor rotational speed corresponding to 0~Max.
operation frequency
14: Output current corresponding to 0~1000A
15: Output voltage corresponding to 0~1000V
16:: Output torque corresponding to (-200%~200%)
motor rated torque
0
☆
b6-01
AO1 output function
selection
0
☆
b6-02
AO2 output function
selection
1
☆
b6-03
Maximum FMP output
frequency
0.01 kHz ~100.00 kHz
50.00 kHz
☆
b6-04 AO1 offset coefficient
-100.0% ~100.0%
0.0%
☆
b6-05 AO1 gain
-10.00~10.00
1.00
☆
b6-06 AO2 offset coefficient
-100.0% ~100.0%
0.00%
☆
b6-07 AO2 gain
-10.00 ~10.00
1.00
☆
Group b7 : Virtual DI (VDI)/Virtual DO (VDO)
b7-00 VDI1 function selection
0~49
0
★
b7-01 VDI2 function selection
0~49
0
★
b7-02 VDI3 function selection
0~49
0
★
b7-03 VDI4 function selection
0~49
0
★
b7-04 VDI5 function selection
0~49
0
★