EM15 User’s Manual
5. Description of Function Codes
61
Diagram 5-21 Corresponding relationship between analog input and setting values
b5-11 (AI1 filting time) is used to set the software filter time of AI1. If the analog input is liable to interference,
increase the value of this parameter to stabilize the detected analog input. However, increase of the AI filter time will
slow down the response of analog detection. Set this parameter properly based on actual conditions.
In different applications, 100% of analog input corresponds to different nominal values. Fordetails, refer to the
description of different applications.
For the setting method of AI curve 2 and AI cure 3, please refer to AI curve 1.
b5-22
AI curve 4 minimum input
Default
0.00V
Setting Range
-10.00V~b5-24
b5-23
Corresponding setting of AI curve 4 minimum input
Default
0.0%
Setting Range
-100.0%~+100.0%
b5-24
AI curve 4inflection point 1 input
Default
3.00V
Setting Range
b5-21~b5-26
b5-25
Corresponding settingof AI curve 4 inflection point 1 input
Default
30.0%
Setting Range
-100.0%~+100.0%
b5-26
Corresponding settingof AI curve 4 inflection point 2 input
Default
6.00V
Setting Range
b5-23~b5-27
b5-27
AI curve 4 inflection point 2 input
Default
60.0%
Setting Range
-100.0%~+100.0%
b5-28
AI curve 4 Maximum input
Default
10.00V
Setting Range
b5-27~+10.00V
b5-29
Corresponding settingof AI curve 4 Maximum input
Default
100.0%
Setting Range
-100.0%~+100.0%
b5-30
AI curve 5 minimum input
Default
-10.00V
Setting Range
-10.00V~b5-31
b5-31
Corresponding settingof AI curve 5 minimum input
Default
-100.0%
Setting Range
-100.0%~+100.0%
b5-32
AI curve 5 inflection point 1 input
Default
-3.00V
Setting Range
b5-28~b5-33
b5-33
Corresponding settingof AI curve 5 inflection point 1 input
Default
-30.0%
Setting Range
-100.0%~+100.0%
b5-34
AI curve 5 inflection point 2 input
Default
3.00V
Setting Range
b5-31~b5-35
b5-35
Corresponding settingof AI curve 5 inflection point 2 input
Default
30.0%
Setting Range
-100.0%~+100.0%
b5-36
AI curve 5 Maximum input
Default
10.00V
Setting Range
b5-33~+10.00V
b5-37
Corresponding settingof AI curve 5 Maximum input
Default
100.0%
Setting Range
-100.0%~+100.0%
b5-38
AI1 jump point
Default
0.0%
Setting Range
-100.0%~100.0%
b5-39
AI1 jump amplitude
Default
0.5%
Setting Range
0%~100.0%
b5-40
AI2 jump point
Default
0.0%
Setting Range
-100.0%~100.0%
b5-41
AI2 jump amplitude
Default
0.5%
Setting Range
0%~100.0%
b5-42
AI3 jump point
Default
0.0%
Setting Range
-100.0%~100.0%
b5-43
AI3 jump amplitude
Default
0.5%
Setting Range
0%~100.0%