Table 5-1: Control Unit Readings
(continued)
Category
Parameter
Description
MENU
Relay
D811
RL1 Ops
This indicates the number of operations carried
out by relay RL1. It can be re-set to zero by
pressing the
red (enter)
button when displaying
D811.
The operation count is used by the Relay
Operations Alarm feature (see
RELAY
→
RELAY
OPERATIONS
D812 to D815
D812 to D815 are the operation counters for
other relays.
RELAY
→
RELAY
OPERATIONS
D820
Relay Status
This indicates a series of 0 and 1 digits which
represent the de-energized (0) or energized (1)
relays.
The first digit represents Relay RL1, the second
digit represents Relay RL2, etc.
RELAY
→
Relay Status
D821
RL1 Run-Time
This indicates the total time that relay RL1 has
been energized for the present relay operation. It
is cumulative i.e. does not reset when the relay
RL1 is de-energized.
The run-time is used by the Relay Run Time Alarm
feature. (see
RELAY
→
RELAY RUN
TIME
D822 to D825
D822 to D825 are the running times for the other
relays.
Totalizer
(Rosemount
3491 only)
D828
Totalizer
This indicates the totalizer count.
See
Set-up totalizing on the Rosemount 3491
details of the totalizing feature on the 3491.
Totalizer
Totalizer
(Rosemount
3492 and 3493
only)
D828
Totalizer 1
This indicates the Totalizer 1 count.
See
Set-up totalizing on the Rosemount 3492
details of the totalizing feature on the Rosemount
3492.
See
Set-up totalizing on the Rosemount 3493
details of the totalizing feature on the Rosemount
3493.
TotalizerTotalizer
D829
Totalizer 2
This displays the Totalizer 2 count.
See
Set-up totalizing on the Rosemount 3492
details of the totalizing feature on the 3492.
See
Set-up totalizing on the Rosemount 3493
details of the totalizing feature on the 3493.
Alarm report
D830
Alarm report
This is for viewing live alarms.
The highest priority alarm is listed first. Use the
up/down arrow
buttons to scroll through the list
if more than one alarm exists. If there are no live
alarms, the alarm report indicates “none”.
See
reporting features.
Alarm report
Reference Manual
Service and troubleshooting
00809-0100-4841
January 2021
Emerson.com/Rosemount
143
Summary of Contents for Rosemount 3490 Series
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual January 2021 00809 0100 4841 8 Emerson com Rosemount ...
Page 16: ...Control unit overview Reference Manual January 2021 00809 0100 4841 16 Emerson com Rosemount ...
Page 36: ...Installation Reference Manual January 2021 00809 0100 4841 36 Emerson com Rosemount ...
Page 134: ...Getting started Reference Manual January 2021 00809 0100 4841 134 Emerson com Rosemount ...
Page 184: ...Additional features Reference Manual January 2021 00809 0100 4841 184 Emerson com Rosemount ...
Page 189: ...Reference Manual 00809 0100 4841 January 2021 Emerson com Rosemount 189 ...