![Emerson Rosemount 3490 Series Reference Manual Download Page 160](http://html.mh-extra.com/html/emerson/rosemount-3490-series/rosemount-3490-series_reference-manual_2400788160.webp)
Uo
Io
Po
La
Ca
Safety
parameter
+27.3 V
96.9 mA
0.66 W
2.26 mH
70 nF
B.4
Europe
B.4.1
I1 ATEX Intrinsically Safe
Certificate
Sira 06ATEX7128 (Wall Mount)
Sira 06ATEX7129X (Panel Mount)
Standards
EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007
Markings
II(1) G D, [Ex ia] IIC, [Ex ia Da] IIIC
Ambient temperature: –40 °C to +55 °C
(See also
ATEX and IECEx conditions for safe use (I1 and I7)
)
Specific Conditions of Use (X):
1. For Sira 06ATEX7129X: Terminal 30 must be connected to a high integrity earth/
ground point in a non-hazardous area.
B.5
International
B.5.1
I7 IECEx Intrinsically Safe
Certificate
IECEx SIR 06.0104X
Standards
IEC 60079-0:2011, IEC 60079-11:2011
Markings
Intrinsically safe for [Ex ia] IIC, [Ex ia Da] IIIC
Ambient temperature: –40 °C to +55 °C
(See also
ATEX and IECEx conditions for safe use (I1 and I7)
)
Uo
Io
Po
Li
Ci
Safety
parameters
+27.3 V
96.9 mA
0.66 W
0.22 mH
0.6 nF
Specific Conditions of Use (X):
1. Terminal 30 of the panel mount control unit (349***P7***) shall be earthed/
grounded in the safe area using a high integrity earth/ground.
Product certifications
Reference Manual
January 2021
00809-0100-4841
160
Emerson.com/Rosemount
Summary of Contents for Rosemount 3490 Series
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual January 2021 00809 0100 4841 8 Emerson com Rosemount ...
Page 16: ...Control unit overview Reference Manual January 2021 00809 0100 4841 16 Emerson com Rosemount ...
Page 36: ...Installation Reference Manual January 2021 00809 0100 4841 36 Emerson com Rosemount ...
Page 134: ...Getting started Reference Manual January 2021 00809 0100 4841 134 Emerson com Rosemount ...
Page 184: ...Additional features Reference Manual January 2021 00809 0100 4841 184 Emerson com Rosemount ...
Page 189: ...Reference Manual 00809 0100 4841 January 2021 Emerson com Rosemount 189 ...