![Emerson Rosemount 3490 Series Reference Manual Download Page 37](http://html.mh-extra.com/html/emerson/rosemount-3490-series/rosemount-3490-series_reference-manual_2400788037.webp)
4
Getting started
4.1
First time power-up
4.1.1
Switching on the Rosemount 3491/3493
The Rosemount 3491/3493 accepts the input from a single HART
®
or 4–20 mA
transmitter.
Procedure
Connect the transmitter to the Current Input terminals on the control unit.
Related information
Electrical installation
Control functionality
4.1.2
Switching on with one new HART transmitter connected
After applying power, the control unit first displays the control unit version e.g.
Rosemount 3491 and the software version. It then automatically searches for a HART
transmitter.
Figure 4-1: Searching for HART Transmitter
Re-connecting to
Digital Transmitter
Please Wait
Re-connecting to
Digital Transmitter
Please Wait
Re-connecting to
Digital Transmitter
Please Wait
A
B
C
A. Start of search
B. After 3 seconds
C. After 15 seconds
A HART transmitter with the factory default polling address of 0 is found after 15 seconds.
When found by the controller, it is designated "Tx1" (Transmitter 1) and assigned to
Channel 1.
However, if the polling address is in the range 1 to 15, a prompt appears allowing the
polling address and the tag name to be changed. This is optional, and selecting the
red
(enter)
button continues the start-up process.
At this time, the control unit reads parameters from the HART transmitter and makes
them available for local interrogation and programming within the control unit menu
system.
Reference Manual
Getting started
00809-0100-4841
January 2021
Emerson.com/Rosemount
37
Summary of Contents for Rosemount 3490 Series
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual January 2021 00809 0100 4841 8 Emerson com Rosemount ...
Page 16: ...Control unit overview Reference Manual January 2021 00809 0100 4841 16 Emerson com Rosemount ...
Page 36: ...Installation Reference Manual January 2021 00809 0100 4841 36 Emerson com Rosemount ...
Page 134: ...Getting started Reference Manual January 2021 00809 0100 4841 134 Emerson com Rosemount ...
Page 184: ...Additional features Reference Manual January 2021 00809 0100 4841 184 Emerson com Rosemount ...
Page 189: ...Reference Manual 00809 0100 4841 January 2021 Emerson com Rosemount 189 ...