![Emerson Micro Motion 4200 Configuration And Use Manual Download Page 93](http://html.mh-extra.com/html/emerson/micro-motion-4200/micro-motion-4200_configuration-and-use-manual_104632093.webp)
8 Integrate the meter with the control
system
8.1 Configure the transmitter channels
Display
Menu
>
Configuration
>
Inputs/Outputs
>
Channel
x
ProLink
Device Tools
>
Configuration
>
I/O
>
Channels
>
Channel
x
Field Communicator
Configure
>
Manual Setup
>
Inputs/Outputs
>
Channel
x
Your transmitter uses Channels A and B to support the control system and communications. Channel B is
configurable.
Depending on your purchase order, some channels may not be activated on your device. To see which
channels are activated:
•
Using the display:
Menu
>
About
>
Licenses
•
Using ProLink:
Device Information
•
Using the Field Communicator:
Overview
>
Device Information
>
Licenses
>
Permanent Feature Set
>
Input/Output Channels
To activate additional channels, contact customer service.
Important
The channel configuration must match the I/O wiring.
Prerequisites
Plan your channel assignments before configuring channels. Not all combinations are supported. For
example:
•
You cannot have two discrete outputs and a frequency output.
.
Important
To avoid causing process errors:
•
Configure the channels before configuring the outputs.
•
Before changing the channel configuration, ensure that all control loops affected by the channel are under
manual control.
Procedure
1. Identify the channels that are activated on your device.
2. For Channel B, if activated, set
Channel Type
as desired.
Configuration and Use Manual
Integrate the meter with the control system
MMI-20048166
April 2019
Configuration and Use Manual
93