38
ADVANCED USER GUIDE
IP66/Nema 4X variable speed drive
MENU 3: FREQUENCY THRESHOLDS - ENCODER OPTION
CONTROL TECHNIQUES
3854 en - 03.2008 / b
3.47
Not used
to
3.50
3.51
Vmin alarm threshold
R-W
0 to 500 rpm
90 rpm
3.52
V max alarm threshold
R-W
0 to 500 rpm
90 rpm
3.53
Not used
to
3.60
3.61
Frequency input source
R-W/P
0.00
to
21.51
0.00
3.62
Input frequency
RO/P
0 to 5000 Hz
-
-
3.63
Maximum frequency output reference
R-W
0 to 1000.0 Hz
20.0 Hz
3.64
Frequency output reference scale
R-W
0 to 32.00
1.00
3.65
Frequency output reference
RO/P
0 to 100%
-
-
3.66
Not used
3.67
Frequency input select
R-W
0 or 1
0
3.68
Minimum frequency threshold
R-W
1.0 to 10.0 Hz
1.0 Hz
3.69
Not used
and
3.70
3.71
Frequency output reference source
R-W/P
0.00
to
21.51
0.00
3.72
Frequency output period
RO/P
0.001 to 2.000 s
-
-
3.73
Frequency output signal
RO/P
0 or 1
-
-
Parameter
Name
Type
Adjustment range
Factory setting
User
setting