MENU 11: SERIAL LINK - DRIVE CHARACTERISTICS - MISCELLANEOUS
CONTROL TECHNIQUES
3854 en - 03.2008 / b
13.3 - Explanation of parameters in
menu 11
to
: Menu 0 set-up
Adjustment range :
0.00
to
21.51
Factory setting
: See table below.
These parameters are used, in order, to define parameters
46
to
65
in menu 0. These parameters are independent of
the preset configuration.
: Parameter scaling
Adjustment range : 0 to 9.999
Factory setting
: 1.00
This is a multiplication coefficient applied to the motor speed
for expressing the speed in a unit defined by the user (see
5.34
).
Example: To obtain a reading in m/min for an application
where the product is moving 200 mm for each motor
revolution ==>
11.21
= 0.2.
: Unit displayed at power-up
Adjustment range : 0 to 5
Factory setting
: 0
0 (Speed) (Spd): On power-up, the speed is displayed.
The unit depends on the setting of
5.34
(frequency in Hz,
speed in rpm or a unit defined by the user).
1 (Load) (Load): On power-up, the load is displayed.
The unit displayed depends on the setting of
4.21
(motor
load as a % or output current in A).
2 (Speed/Load) (SP.Ld): Displays the speed and the load
alternately, or the current. The display time of each value can
be configured in
11.47
.
3 (USER) (USER): On power-up, the user parameter
selected by
11.49
is displayed.
4 (Speed/User) (SP.US): On power-up, the speed and the
user parameter selected by
11.49
are displayed alternately.
5 (Load/User) (Ld.US): On power-up, the load and the user
parameter selected by
11.49
are displayed alternately.
: Serial address
Adjustment range : 0 to 247
Factory setting
: 1
Used to define the drive address in the case of control or
supervision via the serial link in Modbus RTU. Avoid values
containing a zero as they are used to address groups of
drives.
: Serial mode
Adjustment range : 0 or 1
Protocol used for communication via the serial link.
0 (LS NET) (LSnt): LS Net protocol.
1 (Modbus RTU) (rtu): Modbus RTU protocol.
: Baud rate
Adjustment range : 0 to 9
Factory setting
: 6
Used to select the data transfer speed in Modbus RTU.
Note: If the CT Comms cable is used, the baud rate is limited
to 38400 baud.
: Min comms transmit delay
Adjustment range : 0 to 250 ms
Factory setting
: 2 ms
As the serial link is 2-wire type, Rx is connected to Tx and Rx\
to Tx\. A communication fault may occur if the receiver
responds to a request before the sender has had time to
switch. Parameter
11.26
is used to introduce a time between
reception and the data feedback. After transmitting a request,
the drive requires 1.5 ms before receiving the next command.
The adjustment is made in 2 ms intervals.
: Modbus RTU frame format
Adjustment range : 0 to 3
Factory setting
: 0
0 (NONE,2STOP) (OP.2S): No parity, 2 stop bits
1 (NONE,1STOP) (OP.1S): No parity, 1 stop bit
2 (EVEN,STOP) (eP.1S): Even parity, 1 stop bit
3 (ODD,1STOP) (oP.1S): Odd parity, 1 stop bit
: Not used
: Drive software version
Adjustment range : 1.00 to 9.99
Indicates the drive software version.
Parameter
Default value
Menu 0 destination
11.01
6.04
46
11.02
8.10
47
11.03
7.15
48
11.04
7.33
49
11.05
8.41
50
11.06
1.05
51
11.07
1.10
52
11.08
1.29
53
11.09
1.30
54
11.10
2.04
55
11.11
2.06
56
11.12
2.07
57
11.13
6.01
58
11.14
6.09
59
11.15
5.18
60
11.16
5.06
61
11.17
5.11
62
11.18
5.12
63
11.19
11.42
64
11.20
11.43
65
11.01
11.20
11.21
11.22
11.25
LCD display
(kbaud)
LED display
(baud)
0
0.3
300
1
0.6
600
2
1.2
1200
3
2.4
2400
4
4.8
4800
5
9.6
9600
6
19.2
19200
7
38.4
38400
8
57.6
57600
9
115.2
115200
11.23
11.24
11.25
11.26
11.27
11.28
11.29