4.1 - List of parameters in Menu 2
Parameter
Name
Type
Adjustment range
Factory setting
User
setting
2.01
Post-ramp reference
RO/P
If
1.10
= 0 and
2.02
= 0:
-
-
0 to
1.06
If
1.10
= 0 and
2.02
= 1:
1.07
to
1.06
If
1.10
= 1: ±
1.06
2.02
Ramp bypass (
)
R-W
0 or 1
0
2.03
Ramp hold
R-W
0 or 1
0
2.04
Deceleration ramp mode select
R-W
0 to 3
1
2.05
Not used
2.06
S ramp enable
R-W
0 or 1
0
2.07
S ramp acceleration limit
R-W
2 to 10
10
2.08
Standard ramp voltage
R-W
T = 0 to 800 V
Eur: 690V
USA: 750V
2.09
Not used
2.10
Acceleration rate selector
R-W
0 to 9
1
2.11
Acceleration rate 1
R-W
0.1 to 600.0 s/1000 rpm
3.0 s/1000 rpm
to
to
2.18
Acceleration rate 8
2.19
Jog acceleration rate
R-W
0.1 to 600.0 s/1000 rpm
0.2 s/1000 rpm
2.20
Deceleration rate selector
R-W
0 to 9
1
2.21
Deceleration rate 1
R-W
0.1 to 600.0 s/1000 rpm
5.0 s/1000 rpm
to
to
2.28
Deceleration rate 8
2.29
Jog deceleration rate
R-W
0.1 to 600.0 s/1000 rpm
0.2 s/1000 rpm
2.30
Not used
to
2.50
2.51
Ramp hold condition
R-W
0 or 1
0