Menu 15
I/O options
Commander SK Advanced User Guide
173
Issue Number: 9
Figure 10-44 Menu 15A logic diagram*
* x in the parameter boxes represents Menu 15 (i.e.
x.04 =
Pr
15.04)
15.54
Drive encoder position
0 to 65535 (1/2
16
ths of a
revolution)
BW
15.55
Drive encoder speed feedback
-32000 to +32000 rpm
BW
15.56
Maximum drive encoder reference
0 to 32000 rpm
1500
BR
15.57
Drive encoder reference level
-100% to +100%
BW
15.58
Drive encoder reference scaling
0.000 to 4.000
1.000
BR
15.59
Drive encoder reference destination
Pr
0.00
to Pr
21.51
Pr
0.00
Drive reset
15.60
Encoder reset
OFF(0) or On(1)
OFF(0)
Encoder only
13ms. All I/O
routed 30ms
Parameter
Range
Default
Setting
Update Rate
T5
x.04
Monitor
x.14
Invert
x.24
Destination
0.00
21.51
Default
destination
Pr
0.00
T6
x.05
Monitor
x.15
Invert
x.25
Destination
0.00
21.51
Default
destination
Pr
0.00
T7
x.06
Monitor
x.16
Invert
x.26
Destination
0.00
21.51
Default
destination
Pr
0.00
x.27
0.00
x.17
Invert
Default
source
Pr
0.00
21.51
0V
x.07
Monitor
T21
T23
Relay
source
XX
XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
XX
XX
Summary of Contents for 2202
Page 199: ......
Page 200: ...0472 0001 09 ...