10.15 Menu 15: Solutions Module set-up
Figure 10-43 Location of Solutions Module slot
The Solutions Module must be installed when the drive is powered down.
Parameters common to all catergories
The Solutions Module ID indicates the type of module that is installed in the slot.
Table 10-26 Solutions Module ID
When a Solutions Module is installed to the Commander SK for the first time, when the drive is powered up, the drive will trip on SL.dF. Power down
and power back up. The Commander SK automatically saves the appropriate information for the Solutions Module. If a Solutions Module is removed,
when the drive is next powered up, the drive will trip on SL.nF. To clear this trip a parameter save needs to be performed.
Parameter
Range
Default
Update rate
Pr
15.01
Solutions Module ID
0 to 599
Write on power up
Pr
15.02
Solutions Module software version
00.00 to 99.99
Write on power up
Pr
15.50
Solutions Module error status
0 to 255
BR
Pr
15.51
Solutions Module software sub-version
0 to 99
Write on power up
Solutions Module ID
Module
Category
0
No module installed
203
SM-I/O Timer
Automation
204
SM-PELV
205
SM-I/O 24V Protected
206
SM-I/O 120V
207
SM-I/O Lite
208
SM-I/O 32
401
SM-LON
Fieldbus
403
SM-Profibus DP
404
SM-Interbus
407
SM-Devicenet
408
SM-CANopen
410
SM-Ethernet
421
SM-EtherCAT
NOTE