Menu 11
Commander SK Advanced User Guide
139
Issue Number: 9 www.controltechniques.com
These parameters define the parameters that reside in the programmable area in level 2 of the basic parameter set.
When customer defined units are selected as the display units this parameter is used to scale the RPM (Pr
5.04
) to give the displayed units. See
Pr
When speeds greater than 9999 rpm are to be displayed, set Pr
11.21
to 0.1 or 0.01.
Example:
Maximum speed of 30000 rpm. Set Pr 11.21 to 0.1, 30000 rpm = 3000 on display
0
: OFF Frequency (Pr
2.01
)
1
: On Percentage load (Pr
4.20
)
This parameter defines which parameter is displayed at power-up, either the speed or the load. This parameter is written to automatically when the
user switches between speed and load indications in parameter status mode by holding the Mode button down for a period of 2 seconds. In this case
the parameter is saved automatically by the drive, if the user changes this parameter using serial communication it is not saved automatically.
This parameter is used to define the unique address for the drive for the serial interface. The drive is always a slave.
11.01
Pr 61 set-up {71}
11.02
Pr 62 set-up {72}
11.03
Pr 63 set-up {73}
11.04
Pr 64 set-up {74}
11.05
Pr 65 set-up {75}
11.06
Pr 66 set-up {76}
11.07
Pr 67 set-up {77}
11.08
Pr 68 set-up {78}
11.09
Pr 69 set-up {79}
11.10
Pr 70 set-up {80}
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
2
1
1
1
1
Range
Pr
1.00
to Pr
21.51
Default
Pr
0.00
Update rate
Background
11.11 to 11.20
Unused parameters
11.21
Customer defined scaling {24}
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
3
1
1
1
Range
0.000 to 9.999
Default
1.000
Update rate
Background
11.22
Parameter displayed at power-up
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Range
OFF(0) or On(1)
Default
OFF(0)
Update rate
N/A
11.23
Serial comms address {44}
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Range
0 to 247
Default
1
Update rate
Background
NOTE
Summary of Contents for 2202
Page 199: ......
Page 200: ...0472 0001 09 ...