Menu 8
Commander SK Advanced User Guide
115
Issue Number: 9 www.controltechniques.com
Setting this parameter to On(1) causes the relay sense to be inverted.
This word is used to determine the status of the digital I/O by reading one parameter.
Pr
8.20
contains a binary value ‘xx’. This binary value is determined by the state of Pr
8.01
to Pr
8.07
. So for example, if all terminals were active the
value displayed in Pr
8.20
would be the sum of the binary values shown in the table, i.e. 95.
The terminal configuration for Terminal B4, B5 and B6 can be changed using Pr
6.04
.
Destination parameters define the parameter each of the programmable inputs is to control. Only parameters which are not protected can be
controlled by the programmable digital inputs. If a non-valid parameter is programmed, the digital input is not routed anywhere.
Source parameters define the parameter to be represented by the digital output terminal. Only valid parameters can be selected as a source for a
digital output. If a non-valid parameter is programmed, then the digital output will remain in the inactive state.
8.16
Unused parameter
8.17
Status relay invert
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Range
OFF(0) or On(1)
Default
OFF(0
Update rate
2 ms
8.18 to 8.19
Unused parameters
8.20
Digital I/O read word {90}
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
Range
0 to 95
Update rate
Background
Binary value
for xx
Digital I/O
1
Terminal B3
2
Terminal B4
4
Terminal B5
8
Terminal B6
16
Terminal B7
64
Terminal T5/T6
8.21
Terminal B3 digital input destination/output source
8.22
Terminal B4 digital input destination
8.23
Terminal B5 digital input destination
8.24
Terminal B6 digital input destination
8.25
Terminal B7 digital input destination
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
2
1
1
1
1
Range
Destination: Pr
0.00
to Pr
21.51
Source: Pr
0.00
to Pr
21.51
Update rate
Read on drive reset
Parameter
Function
Default Setting
Description
8.21
Terminal B3 digital input destination/output source
10.03
Zero Speed (Output)
8.22
Terminal B4 digital input destination
6.29
Enable
8.23
Terminal B5 digital input destination
6.30
Run forward
8.24
Terminal B6 digital input destination
6.32
Run Reverse
8.25
Terminal B7 digital input destination
1.41
Reference select
8.26
Unused parameter