Defines the current level used during DC injection braking as a percentage of motor rated current as defined by Pr
5.07
.
Defines the time of injection braking where this is specified in stopping modes 2 to 4 (see Pr
6.05
Unused parameter
6.06
Injection braking level
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
1
Range
0.0 to 150.0%
Default
100.0
Update rate
Background
6.07
Injection braking time
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
Range
0.0 to 25.0 s
Default
1.0
Update rate
2 ms
B2
B4
B5
B6
+24V
Enable
Run
Forward/Reverse
Pr 6.04=2
B2
B4
B5
B6
+24V
/Stop / Run Permit
Run
Forward/Reverse
Pr 6.04=3
B2
B4
B5
B6
+24V
/Stop / Run Permit
Run
Jog
Pr 6.04=4
B2
B4
B5
B6
+24V
User Programmable
Run Forward
Run Reverse
Pr 6.04=5
B2
B4
B5
B6
+24V
User Programmable
User Programmable
User Programmable
Pr 6.04=6