56
Scout 320 REV 3:2018
F1 Parameter List Accessed without passcode
Parameter NO
Parameter name
Parameter description
Barfeeder Monitor
L01
Finished product length
Use the Bar end position to generate a signal for bar end.
L02
Feed too long safety of
chuck close
Prevents bars from feeding over the length of finished product. To
disable parameter function, please set the value to zero.
L03
Feed too short safety of
chuck close
Prevents bars from feeding length less than finished product. To
disable parameter function, please set the value to zero.
L04
Bar pusher move forward
of chuck open
Under automatic mode, the bar pusher move forward and the
distance is large than the setting value during chuck opened.
L05
Bar pusher backward
safety of chuck open
Under automatic mode, when the bar pusher move backward and
the distance is large than the setting value during chuck opened.
S01
Speed of chuck open
The speed of the bar pusher moves forward under automatic mode
and the chuck is opened.
Q01
Torque of chuck open
The torque of the bar pusher moves forward when the chuck is
opened under automatic mode.
S02
Speed of chuck close
The speed of the bar pusher moves forward under automatic mode
and the lathe chuck is closed.
Q02
Torque of chuck close
The torque of the bar pusher moves forward when the chuck is
closed under automatic mode.
S03
Manual feed speed
The motor turning speed when the bar pusher move forward under
manual mode.
Q03
Torque of manual
The motor torque of the bar pusher moves forward or backward
under manual mode.
P01
Movable anti-vibration
opening position
The position of the movable anti-vibration device opened under
automatic operation.
P02
Movable anti-vibration
second close position
The Second close position of movable anti-vibration device stands
for the position of bar pusher is over the value of parameter,
P01;
the anti-vibration can operate the second close function to clamp bar
pusher.
P19
Chuck facing distance
fine tuning
Fine tuning for chuck facing position as the datum of chuck facing
distance
P10
. If the adjustment quantity is less than 200 or large
than 200, please adjust the value of chuck facing distance
P10
.
P20
Bar end position fine
tuning
Fine tuning for the bar end position. If the fine tuning quantity is less
than 200 or large than 200, then adjust the parameter
P11
,
bar end
position value.
P22
Movable anti-vibration
early close position
Under Auto-Mode, Anti-vibration Device will close when bar
pusher reached this parameter setup position.