93
Scout 320 REV 3:2018
Alarm Cure
CURE
※
Check for correct sensor placement.
※
Check
LS07 Channel Close Switch
and
LS08 Channel Open
Switch
for loose or damaged wiring
※
Check for correct sensor placement.
※
Check
LS05 Pusher Introduction Switch
and
LS06 Pusher
Extraction Switch
for loose or damaged wiring
※
Check the alarm No. on
LCD
display of servo whether it is
abnormal. If yes, please contact Edge Technologies for
troubleshooting.
※
Servo has been stalled, check for obstruction.
※
Check the pusher torque and speed parameters that they are
not too high or too low.
※
Check the bar feeder was in auto status when
CNC
is
machining normally, otherwise bar feeder can’t feed material.
※
Check the power
0.L1
for oil pump. Breaker has tripped, reset
breaker.
※
increase the amperage on the circuit breaker.
※
Oil pump is locked and won’t rotate.
※
Contact Edge Technologies for troubleshooting assistance.
※
Close bar feeder cover
※
Check for correct sensor placement.
※
Check any foreign body jamming on
S04 Measurement
Sensor
.