64
Scout 320 REV 3:2018
Parameter description: The torque of the bar pusher pushes out remnant
when receiving bar end signal.
Setting method: Input the required torque.
Note: Set actual torque to avoid crashing. This is only used
when a front eject collet is installed and the process
requires the remnant to be ejected from the lathe
side.
Previous page
Next page
Home page
3.7XL Generally value:
Setting range:
0~800mm
Setting value:
Parameter description: In automatic mode the movable anti-vibration device
must open for the pusher collet to pass without
damage to the rollers or blocks.
Setting method: Position the lathe headstock to the Z limit position
nearest the bar feeder, normally called the Z- over
travel position. Position the pusher collet 1 inch
before the MAVD. Record the position displayed on
the HMI for the parameter value.
Note: If the distance value is too high the MAVD will not
open.
Previous page
Next page
Home page
3.7XL Generally value:
Setting range:
0~5000mm
Setting value:
Parameter description: In automatic mode the movable anti-vibration device
can be closed on the pusher once the pusher collet
has passed the roller/blocks.
Setting method: Add 150mm to the MAVD opening position.
Note: To disable this parameter function, set the value to
zero.
Previous page
Next page
Home page
3.7XL Generally value:
Setting range:
0~5000mm
Setting value: