74
Scout 320 REV 3:2018
Parameter description: This is open collet timeout. If the set time is exceeded
the bar feeder will set ALARM 29 will display and stop
operating.
Setting method: When the setting value is 0, the parameter function
will be disabled.
Previous page
Next page
Home page
3.7XL Generally value:
Setting range:
0~999 seconds
Setting value:
Parameter description: This is closed collet timeout. If the set time is
exceeded the bar feeder will set ALARM 32 will
display and stop operating.
Setting method: When the setting value is 0, the parameter function
will be disabled.
Previous page
Next page
Home page
3.7XL Generally value:
Setting range:
0~999 seconds
Setting value:
Parameter description: This is closed collet push delay. In automatic mode,
pusher pushes bar material into lathe and collet close
to work. Once the collet closes the pusher will
continue to push for the set time.
Setting method: Input the required time.
Note: Setting the time too long may cause alarms.
Previous page
Next page
Home page
3.7XL Generally value:
Setting range:
0~9.9 seconds
Setting value: