95
Scout 320 REV 3:2018
※
Chuck is open when pusher moves forward.
※
Chuck is open when pusher retreats.
※
Chuck close collet timeout exceeded setting.
※
Check lathe program for correct process during automatic
mode.
※
Check lathe emergency stop condition.
※
Check lathe emergency stop signal is wired correctly, Install
condition.
※
Press the power on button
SS2.
※
Bar change time has exceeded.
※
Check for an input or output of the bar change process that is
causing the alarm.
※
Check if loading bar sensor is loose or wiring condition is good.
※
Check if loading motor is running or not.