ECP2010
/
ECP2010H
45 / 68
Setting
Description
COPY DIN2
When digital input 2 is on level L, output is connected. Even in case of
setting digital input on OFF.
6.5. Info
In each submenu is displayed information about the unit and its parts.
The unit contains information about internal components, their serial numbers, versions etc.
All information can be read from computer and serves for clear identification of the unit and its
components.
The unit contains global time counter about service time of the unit (
Menu/Info/Device
).
Based on this time are also recorded events, that have occurred during unit use and for service
needs it is possible to read them using a computer. In the same manner are also recorded
replacements of most important unit components, saved in a special record.
6.5.1. Device
Displays unit name, its serial number and total operating time.
6.5.2. Boards
Displays information about electronic boards in the unit.
BN
- board name,
HW
- board
version,
FW
- firmware version,
UN
- board identification numer.
6.5.2.1. Main Board
Unit main board.
6.5.2.2. Display Board
Board for display and keyboard.
6.5.2.3. XPORT Module
Ethernet communication module.
6.5.3. Ethernet
Displays information about actual setting of ethernet.
IP
-IP address of the unit,
MASK
–
subnet mask,
GATE
–
default gateway,
MAC
–
unique hardware address
6.5.4. User Text
User information about the unit. This information can be set only through PC. It serves for
user description of the unit, its placement etc.
6.5.5. Pump
In this submenu are displayed supplementary information about the pump run from unit start-
up.
REV. COUNT
- camshaft speed (number of piston cycles),
OPER. TIME
- operating time.
6.5.6. Parts
Displays information about replaced pump components. First item is operating time
(pumping) from last replacement and second item is number of revolutions (piston cycles) from last
replacement (speed is in thousands).