background image

TECHNICAL GUIDE

ADD - ON COILS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS

MODELS: MC, PC, FC, HD, HC, UC, MH
600 - 2000 CFM     1.5 - 5 TON COILS

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at

www.ariprimenet.org.

HORIZONTAL CASED

HC

UPFLOW

PARTIAL CASED

PC

HORIZONTAL

DUCT

HD

UPFLOW

UNCASED

UC

UPFLOW/DOWNFLOW

FULL CASED

FC

FULL CASED

MULTI-POSITION

MC

UPFLOW/DOWNFLOW

UNCASED

MH

ISO 9001

Certified Quality

Management System

331471-YTG-A-0507

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

 

Heating

Air Conditioning

R

DESCRIPTION

These cooling and heat pump coils are designed to be installed with
UPG furnaces and to be matched with UPG cooling and heat pump
outdoor units. All UPG coils utilize a TXV to provide our customers
with the optimum performance and refrigerant control required for
13+ SEER systems. Coils can be ordered with a R22 TXV factory
installed that can be easily converted to R410A by changing the bolt-
on TXV.

“Flex-coils”

 are also available without a factory installed metering

device. For added application flexibility a R22 or R410A TXV is
installed, on 

“Flex-coils”, 

in the field to meet your refrigerant choice.

Upflow/Downflow Coils Full Cased and Partial Cased
Coils – 

Designed for high-efficiency to match any system, full cased

in the upflow or downflow and the partial cased in the upflow only
application

.

Multi-Position Coils - 

Designed for high-efficiency like the

upflow/downflow coil but with the added flexibility that allows it to be
installed any position, upflow, downflow, horizontal right or left. This
coil can be easily applied to our furnace and modular air handler in
any configuration.

Horizontal Duct Coils - 

Available for both cooling and heat pump

dedicated horizontal, slab coil, applications. Field transition may be
required

.

Dedicated Horizontal Cased Coils – 

These coils are cooling

only or heat pump approved for horizontal furnace or modular air
handler applications. Unlike the horizontal duct coils these cased
coils match the dimensions of the furnace or modular blower

.

FEATURES

Thermal Expansion Valve - 

Provides flexibility to convert any

coil to R22 or R410A refrigerant. A true bolt-on TXV, valve assembly
and equalizer tube are bolt-on, no brazing required. TXV and sens-
ing bulb are mounted inside the cased coil cabinet. (Must be field
supplied for all “Flex-coils”)

MicroBlue™ Coated Fins - 

All coils are treated with a

MicroBlue™

 Hydrophilic coating to enhance the removal of conden-

sate during the refrigeration cycle and reduce the possibility of water
blow-off. The 

MicroBlue™ 

coating also reduces the growth of germ

causing microbes.

Insulated Cabinet - 

Evaporator coil cabinets are thermally insu-

lated with foil faced insulation to prevent sweatin

g. 

HD coils use

fiberglass turfskin insulation.

Internally Clean - 

All evaporator coils are factory leak-tested,

dehydrated, sealed and shipped with a holding charge. The suction
and liquid lines are sealed with rubber plugs, no cutting of connection
stubs to attach line set

.

Durable Finish Inside and Out - 

Coil casings are made of pre-

painted steel. The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep. All inter-
nal metal parts are made of G90 pre-painted steel i.e. triangular
plates, top plates, horizontal supports etc. (Coil header plates are
non-painted due to the brazing process during production.)

Optimum Heat Transfer - 

Using the latest in heat transfer tech-

nology, staggered rows of copper tubes are mechanically expanded
into aluminum fins to provide optimum air to surface contact for
ample moisture removal as well as high performance ratings.

ACCESSORIES

Refer to Price Manual for specific model numbers

.

TXV Kits

 - 

Thermal expansion valve kits are available for “Flex-coil”

applications and converting R22 to R410A refrigerant or as a service
replacement. All TXV kits are non-braze

all connections are bolt-on

including the valve assembly and equalizer tube. (No orifice or any
other metering device is to be used in conjunction with the TXV).

Coil Casing Without Coil

 – 

Coil casings are available in each

width that can be installed with the furnace or modular air handler
during initial installation. This option is available to allow the installer
the flexibility to install the coil at a later date without duct modifica-
tions.

Summary of Contents for MH

Page 1: ...coils match the dimensions of the furnace or modular blower FEATURES Thermal Expansion Valve Provides flexibility to convert any coil to R22 or R410A refrigerant A true bolt on TXV valve assembly and...

Page 2: ...62 36 7 29 2 23 8 19 9 57 31 5 27 6 22 4 18 8 FC36A PC36A 1150 72 46 0 41 9 37 4 32 9 67 36 8 32 5 28 5 24 2 62 28 8 24 1 26 4 19 6 57 24 7 22 9 21 1 19 6 FC36B PC36B FC36C PC36C 1250 72 51 1 46 5 41...

Page 3: ...42 3 37 3 67 41 7 36 8 32 3 27 4 62 32 5 27 3 29 8 22 2 57 27 9 25 8 23 8 22 2 MC36C 1250 72 53 4 48 6 43 4 38 3 67 42 8 37 8 33 1 28 2 62 33 4 28 1 30 6 22 8 57 28 7 26 5 24 5 22 8 MC42B MC42C 1400 7...

Page 4: ...3 41 1 57 71 2 61 4 51 3 41 1 See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity COOLING CAPACITY COIL ONLY Model Rated CFM Entering Air F Wet Bulb MBH E...

Page 5: ...9 2 44 9 67 69 4 57 2 45 2 33 1 62 54 0 42 3 33 4 26 8 57 46 4 40 0 33 4 26 8 UC48C UC48D 1600 72 62 4 56 8 50 5 44 4 67 57 4 53 2 46 5 40 5 62 47 1 42 8 38 1 33 2 57 44 3 40 3 35 8 31 2 UC60C UC60D 1...

Page 6: ...0 34 FC48C PC48C 1600 0 29 1800 0 35 2000 0 40 2200 0 46 FC48D PC48D 1600 0 25 1800 0 30 2000 0 35 2200 0 40 FC60C PC60C 1600 0 28 1800 0 33 2000 0 38 2200 0 43 FC60D PC60D 1600 0 21 1800 0 27 2000 0...

Page 7: ...30 1600 0 35 1800 0 41 MC48D 1200 0 20 1400 0 26 1600 0 31 1800 0 36 MC60D 1600 0 27 1800 0 33 2000 0 38 2200 0 44 MC61D 1600 0 24 1800 0 29 2000 0 35 2200 0 40 MC62D 1600 0 24 1800 0 29 2000 0 34 UN...

Page 8: ...12 2 16 x 17 5 1 x 0 866 3 8 Enhanced 2A 55 47 FC35B3XN2 PC35B3XN2 3 9 3 12 2 16 x 17 5 2A 53 45 FC35C2AN1 PC35C2AN1 3 9 3 12 2 16 x 17 5 2A 57 48 FC35C3XN 1 2 PC35C3XN2 3 9 3 12 2 16 x 17 5 None 55 4...

Page 9: ...H1 Cooling Heat Pump Sweat 5 83 3 12 28 x 30 1 x 0 866 3 8 Enhanced None 46 HD60S2CH1 2C 48 UNCASED UPFLOW A TYPE Model Application Refrig Conn Types Face Area Sq Ft Rows Deep Fin Per In Coil Size Tub...

Page 10: ...2C2CH1 2C MC43C2CH1 Cooling Heat Pump Sweat 4 86 3 12 2 20 x 17 5 1 x 0 866 3 8 Enhanced 2C 75 MC48C3XH1 Cooling Heat Pump Sweat 5 35 3 12 2 22 x 17 5 1 x 0 866 3 8 Enhanced None 82 MC48C2CH1 2C MC48D...

Page 11: ...32 19 7 8 20 3 8 7 8 None MC30B2AH1 17 5 26 5 16 3 8 16 5 3 8 3 4 A MC48D2CH1 24 5 32 23 3 8 23 5 3 8 7 8 C MC30B3XH1 17 5 26 5 16 3 8 16 5 3 8 3 4 None MC48D3XH1 24 5 32 23 3 8 23 5 3 8 7 8 None MC35...

Page 12: ...8 7 8 None FC30B2AN1 17 5 22 16 3 8 16 5 3 8 3 4 A FC48D2CN1 24 5 28 23 3 8 23 5 3 8 7 8 C FC30B3XN1 17 5 22 16 3 8 16 5 3 8 3 4 None FC48D3XN1 24 5 28 23 3 8 23 5 3 8 7 8 None FC35B2AN1 17 5 20 16 3...

Page 13: ...8 20 3 8 7 8 C PC30A3XN1 14 5 21 7 8 13 3 8 13 5 3 8 3 4 None PC43C3XN1 21 22 5 8 19 7 8 20 3 8 7 8 None PC30B2AN1 17 5 21 3 8 16 3 8 16 5 3 8 3 4 A PC48C2CN1 21 25 3 8 19 7 8 20 3 8 7 8 C PC30B3XN1...

Page 14: ...XN1 16 20 5 UC48C3XN1 19 5 23 5 UC24B2AN1 UC48C2CN1 UC30A3XN1 13 21 UC48D3XN1 23 23 UC30A2AN1 UC48D2CN1 UC30B3XN1 16 20 5 UC60C3XN1 19 5 25 5 UC30B2AN1 UC60C2CN1 UC36A3XN1 13 23 5 7 8 UC60D3XN1 23 25...

Page 15: ...S H1 28 3 4 24 23 3 4 21 5 8 3 8 3 4 HD36S H1 28 3 4 28 23 3 4 25 5 8 7 8 HD48S H1 34 3 4 28 29 3 4 25 5 8 HD60S H1 34 3 4 30 29 3 4 27 5 8 COIL MH B COIL SHOWN AS QUICK CONNECT REFER TO FIGURE 2 FOR...

Page 16: ...to change without notice Printed in U S A 331471 YTG A 0507 Copyright by York International Corp 2007 All rights reserved Supersedes 261627 YTG D 0207 Unitary 5005 Norman Products York OK Group Drive...

Reviews: