7 Product-specific CAN objects XN300 slice modules
7.26 XN-322-2SSI
352
Gateway XN-312-GW-CAN
06/16 MN050003-EN www.eaton.eu
7.26.6 Channel Transmission Configuration Register (Object 0x4101, 0x4103)
Objects 0x4101 and 0x4103 contain configuration information regarding the
channel's data transfer.
Design of the data bytes:
Byte 0:
Feature
Description / Value
EDS
Name
State Register Channel
[M8SubExt410x]
Parameter Name=StateRegisterChannel1
ObjectType=0x7
DataType=0x0005
AccessType=rw
PDOMapping=0
Count=1
Description
StateRegisterChannel1
Object 0x4101
StateRegisterChannel2
Object 0x4103
Object Code
ARRAY
Mapping
SDO
Data type
UNSIGNED8
Sub index
01 … FE hex
Access
rw
Byte 0:
Sub index
1
≦
n
≦
254
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Data bit
Designation
Description
Notes
0 – 1
SSI Shift Register Frequency
2
0 = OK
1 = Gray Code Decoding
3
0 = Incremental Encoder Mode
1 = SSI busy (1= busy) (read only)
4
Reserved
5
0 = OK
1 = Error Reset (1 = clear error) (read, write)
6
0 = OK
1 = Start with Sync (1= enable)
7
0 = OK
1 = Continuous Sensor Read
Summary of Contents for XN-312-GW-CAN