7 Product-specific CAN objects XN300 slice modules
7.24 XN-322-1DCD-B35
328
Gateway XN-312-GW-CAN
06/16 MN050003-EN www.eaton.eu
7.24.16 DC Motor I2T Value Limit (Object 0x40E5)
Object 0x40E5 represents the analog shutdown value for the internal mea-
surement of motor energy I²t in [(1/160) A²s].
Design of the data bytes:
Feature
Description / Value
EDS
Name
DCMotorI2TLimit
[MxSubExt40E5]
ParameterName=DCMotorI2TLimit
ObjectType=0x7
DataType=0x0007
AccessType=rw
PDOMapping=1
Count=1
Description
DC Motor I2T Value Limit
Object Code
ARRAY
Mapping
PDO
Manual
Data type
UNSIGNED32
Sub index
01 … FE
hex
Access
rw
Default
0000 0400
hex
1 Byte
Byte 0:
Sub index
1
≦
n
≦
254
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
LSB
4 Byte
3 Byte
Sub index
1
≦
n
≦
254
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
MSB