7.24.5 Read PWM Sequenz Data (Object 0x30E0 to 0x30E3)
Objects 0x30E0 to 0x30E3 can be used to read the motor control PWM out-
put sequence data from the module.
1 Byte
Byte 0:
Sub index
1
≦
n
≦
254
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Bit
Description
0
1 => Activate motor sequence output
1
reserved
2
reserved
3
1 = Activate status message: High motor current (I²t = 16 A²s exceeded)
4
1 = Activate status message: Motor current (3.5 A) too high (additional peripheral reset)
5
1 = Activate status message: DC of module supply OK
6
1 = Activate status message: DC of motor supply OK
7
1 = Activate status message: LED peripheral reset
8
1 = Activate status message: Motor peripheral reset
9
1 = Activate status message: Motor induced voltage too high (additional peripheral reset)
10
1 = Activate overtemperature shutdown
11
1 = Reset 95 °C overtemperature (clear status message)
12
1 = Activate i²t error shutdown
13
1 = Reset i²t error (clear status message)
14
1 = Activate PWM 20 mA LED
15
1 = Activate PWM 3500 mA LED
Summary of Contents for XN-312-GW-CAN
Page 1: ...Manual CANopen Gateway XN 312 GW CAN 06 16 MN050003 EN ...
Page 4: ...II ...
Page 14: ...10 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton com ...
Page 374: ...9 What Happens If 370 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...
Page 388: ...384 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...