Page 1: ...al for a Weblog device with sensor ICU tech GmbH Bahnhofstrasse 2 CH 3534 Signau www icutech ch info icutech ch T 41 34 497 28 20 Support Mo Fr 9 00h 17 00h T 41 34 497 28 20 support icutech ch Druckversion 2019 ...

Page 2: ...tween ICU Gateway and Internet 5 2 4 Connect via Ethernet LAN 5 2 5 Gateway Configuration for WLAN 5 2 6 Connect 7 3 The Weblog Platform 8 4 Access via ICU tech WebLog App 9 4 1 Install App 9 4 2 App Login 10 4 3 App Sensors Overview 10 4 4 App Sensor View 10 4 5 Sign App Event 11 5 Access via Web Browser 12 5 1 Login 12 5 2 Logout 12 5 3 Different Views 12 5 4 Alarm Status Display 12 5 5 Date Tim...

Page 3: ...h www icutech ch 1 Package contents The shipping box contains the following content 1 ICU tech Gateway GW3 2 ICU tech sensors a WLT 20 b WLRHT oder WLRT Depending on order 1 3 sensors 3 Ethernet LAN cabel 5m 4 Power supply unit for 230V 5 Magnetic button 6 Customer information sheet 7 Calibration certificate 1 2a 4 5 3 2b ...

Page 4: ...t about 30 sec 2 2 Sensor Commissioning 2 2 1 Sensor Activation The sensor must be activated with the supplied magnetic button before first use To do this stroke the magnetic button over the sensor at the marked point see pictures below WLT 20 Sensor WLRHT and WLRT Sensor 2 2 2 Sensor Placement Then place the sensor in the cooling unit or at the desired location The distance between the gateway an...

Page 5: ...nection type to choose The configuration app ICU tech Gateway allows IT professionals to configure additional network settings 2 4 Connect via Ethernet LAN Plug the supplied Ethernet cable into the Ethernet port of the ICU gateway and connect it to the company network In case of doubt the person responsible for IT in your company can help Ethernet connection 2 5 Gateway Configuration for WLAN 2 5 ...

Page 6: ... is located on the label on the side of the gateway picture left 2 5 2 3 Step 3 Log in the App on the Gateway In the app select your gateway GW3 and log in with the password 1234 After entering the password confirm with OK 2 5 2 4 Step 4 Connection Types The app offers different connection types You can choose between Ethernet LAN or WLAN WiFi The default connection type is Ethernet LAN with DHCP ...

Page 7: ...ect WiFi DHCP Enter your WLAN network SSID and password passphrase and then save them 2 6 Connect 2 6 1 Test Connection After entering the connection type and the network properties the connection can be checked by clicking on the button TEST CONNECTION 2 6 2 App Displays the Gateway Status The app now shows whether the gateway is online or offline The gateway must be online If not reconnect ...

Page 8: ...er 5 The ICU tech WebLog app is available for Android and IOS The sensors deliver their measurement data via ICU gateway to the ICU tech WebLog server This server monitors the data and triggers an alarm via e mail and SMS in case of a deviation Each alarm must be signed by a user for traceability The signature records the cause of each alarm and which user reacted to the alarm The weblog platform ...

Page 9: ...on the desired smartphone for Android in the Google Play Store or for IOS in the App Store 4 1 1 Download for Android Link to the ICU tech Weblog App for Android https play google com store apps details id ch icu MonitoringApp Store search text ICU tech WebLog 4 1 2 Download for IOS Link to the ICU tech Weblog App for IOS https itunes apple com us app weblog id1441762936 l de ls 1 mt 8 Store searc...

Page 10: ...ist of all sensors appears Sensors with open events warning alarm communication error appear in red letters By tapping on the corresponding sensor a detailed sensor view appears on the screen 4 4 App Sensor View By tapping the corresponding sensor a detailed sensor view appears on the screen In the table of values of the sensor the last sensor value date and time of the last measured value average...

Page 11: ...t yet been signed 4 5 Sign App Event Each event such as a warning or alarm must be signed for traceability The procedure for event signing via the app is 1 Select the alarm warning in the event list 2 The signature panel appears on the screen Enter the name and password in the required place 3 Enter the reason for the alarm in the comment field E g refrigerator filled power failure cleaning etc 4 ...

Page 12: ...nd password press the blue login button or the enter key on the keyboard 3 After successful login the default view of the Boomerang system appears If the name or password is entered incorrectly the error message login cannot be performed appears 5 2 Logout The system can be exited with the blue log out button After logging out the system returns to the Boomerang Web Login window Please always clos...

Page 13: ...en the sensor value has exceeded the warning limit Communication error Is triggered when a communication error is detected in the transmission of measured values from the sensor to the Boomerang server 5 5 Date Time Interval The display of the sensors or of the individual sensor can be shown as desired by date from to click on calendar symbol or as time interval click on blue selection button the ...

Page 14: ...he status icon appears in the list in grey 5 7 Standard Overview After logging in successfully the standard overview appears This shows the user all groups to which he has access A group is typically a practice company name or location such as a laboratory or department In the example below the user has access to the object group named Practice XYZ 5 7 1 Group List Name Status Open posts Last reco...

Page 15: ... of the freezer 5 8 1 Sensor List Name Name oft he sensor Status Sensor status Meanings oft he symbols are described in chapter 4 4 Open positions Number of open events Events Number of alarm events Last measures value Last measured value of the sensor Time Time of the event Mean value Average value of all measurements of the displayed time period Min Lowest measurement of the displayed time perio...

Page 16: ...r the selected period are displayed Below the diagram the sensor ID measuring interval calibration value and time alarm filter and sensor description are displayed 5 9 1 Zooming the Diagram View To zoom use the mouse to mark the desired zoom area from top left to bottom right To reset the zoom area mark the selection with the mouse from bottom right to top left Zoom Reset Name des ausgewählten Sen...

Page 17: ...tech Support The ICU tech support team will be happy to help you with any problems or uncertainties We provide information during office hours from Monday to Friday between 9 00 and 17 00 hours You can reach us by phone or e mail Telefon 41 0 34 497 28 20 Mail support icutech ch Postadresse Bahnhofstrasse 2 CH 3534 Signau Internet www icutech ch ...