33
SPX Advanced application – parameter list
SPX ADVANCED APPLICATION MANUAL
SVCH0203—October 2017 www.eaton.com
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.8.9.24 Iw Offset
–32000
32000
0
670
P1.8.9.25 Estimator Kp
0
32000
1781
P1.8.9.26 Estimator Ki
0
32000
1782
P1.8.9.27 Voltage Drop
0.00
20.00
671
4.8.7.1 Fine tuning parameters
Table 19 . Fine tuning parameters
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.8.10.1 DeadTimeComp.
–10
32000
ns
1751
P1.8.10.2 DeadTieContCurL
–32000
32000
1752
P1.8.10.3 DeadTHWCompDisab
0
1
1750
0=enabled
1=disabled
P1.8.10.4 MakeFluxTime
0
32000
Ms
660
P1.8.10.5 CurrMeasFCompTC
0
65535
1554
700=25us
P1.8.10.6 TCDunDampGain
0
100.00
%
1576
P1.8.10.7 TCDynDampTC
0
32000
ms
1577
P1.8.10.8 CurrLimOptions
0
65535
1702
P1.8.10.9 AdConvStartShift
0
65535
1701
P1.8.10.10 VoltageCorr. Kp
0
32.000
1783
P1.8.10.11 VoltageCorr. Ki
0
32000
1784
P1.8.10.12 GearRatioMultipl
0
32000
1558
P1.8.10.13 GearRatioDivider
0
32000
1559
4.9 Speed control
4.9.1 Speed control basic settings
Table 20 . Speed control basic settings
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.9.1
Load drooping
0.00
100.00
%
0.00
620
P1.9.2
Load drooping time
0
32000
ms
0
656
For dynamic changes
P1.9.3
Load drooping removal
0
2
0
1534
0=Normal
1= At zero Freq Lim
2=Linear zero to Fnom
4.9.2 Speed control OL settings
Table 21 . Speed control OL settings
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.9.4.1
Speed controller P gain
(open loop)
0
32767
3000
637
P1.9.4.2
Speed controller I gain
(open loop)
0
32767
300
638
4.9.3 Speed control CL settings
Table 22 . Speed control CL settings
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.9.5.1
Speed control P gain
0
1000
30
613
P1.9.5.2
Speed control I time
–32000
32000
ms
100
614
Negative value uses 0,1 ms format instead of 1 ms
P1.9.5.3
0-speed time at start
0
32000
ms
100
615
P1.9.5.4
0-speed time at stop
0
32000
ms
100
616