17
SPX Advanced application – parameter list
SPX ADVANCED APPLICATION MANUAL
SVCH0203—October 2017 www.eaton.com
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.2.2
Remote 1 reference
0
17
1
117
See P1.2.1
P1.2.3
Remote 2 reference
0
17
9
122
See P1.2.1
P1.2.4
Remote 1 reference 2
0
17
2
131
See P1.2.1
P1.2.5
Speed share
–300.00
300.00
%
100.00
1241
P1.2.6
Load share
0.0
500.0
%
100.0
1248
4.2.2 Constant reference
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.2.7.1 Jogging speed reference
0.00
320.00
Hz
5.00
124
P1.2.7.2 Preset speed 1
0.00
320.00
Hz
10.00
105
Multi-step speed 1
P1.2.7.3 Preset speed 2
0.00
320.00
Hz
15.00
106
Multi-step speed 2
P1.2.7.4 Preset speed 3
0.00
320.00
Hz
20.00
126
Multi-step speed 3
P1.2.7.5 Preset speed 4
0.00
320.00
Hz
25.00
127
Multi-step speed 4
P1.2.7.6 Preset speed 5
0.00
320.00
Hz
30.00
128
Multi-step speed 5
P1.2.7.7 Preset speed 6
0.00
320.00
Hz
40.00
129
Multi-step speed 6
P1.2.7.8 Preset speed 7
0.00
320.00
Hz
50.00
130
Multi-step speed 7
P1.2.7.9 Inching reference 1
–320.00
320.00
Hz
2.00
1239
P1.2.7.10 Inching reference 2
–320.00
320.00
Hz
–2.00
1240
P1.2.7.11 Speed step
–50.0
50.0
0.0
0.0
1252
9000xDrive speed tuning
4.2.3 Power reference
Table 2 . Power reference input signal selection, G1 .2 .8
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.2.8.1 Power reference
0
8
0
1620
0=Not used
1=AI1
2=AI2
3=AI3
4=AI4
5=AI1 Joystick
6=AI2 Joystick
7=Keypad Ref
8=Fieldbus
P1.2.8.2 Maximum power reference
0.0
300.0
%
120.0
1621
P1.2.8.3 Power reference Increase
rate
0
10000
%/s
100
1622
4.2.4 Torque reference
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.2.9.1 Torque reference selection
0
8
0
641
0=Not used
1=AI1
2=AI2
3=AI3
4=AI4
5=AI1 joystick (–10 – 10 V)
6=AI2 joystick (–10 – 10 V)
7=Torque reference from keypad, R3.5
8=FB Torque reference
9=Master torque
10=Power reference
P1.2.9.2 Torque reference max.
–300.0
300.0
%
100
642
P1.2.9.3 Torque reference min.
–300.0
300.0
%
0.0
643