SPX Advanced application – monitoring values
SPX ADVANCED APPLICATION MANUAL
SVCH0203—October 2017 www.eaton.com
3. SPX Advanced application –
monitoring values
On the next pages you will find the lists of parameters
within the respective parameter groups. The parameter
descriptions are given on pages 45 to 174. Parameter
description includes more than is available in this application
see parameter list what is available.
Column explanations:
Code
= Location indication on the keypad; Shows the
operator the present parameter number
Parameter = Name of parameter
Min
= Minimum value of parameter
Max
= Maximum value of parameter
Unit
= Unit of parameter value; Given if available
Default
= Value preset by factory
Cust
= Customer’s own setting
ID
= ID number of the parameter
_____
= On parameter code: Parameter value can only
be changed after the FC has been stopped.
_____
= Apply the Terminal to Function method (TTF)
to these parameters (see chapter 2)
_____
= Monitoring value is possible to control from
fieldbus by ID number
The manual presents signals that are not normally visible for
monitoring. i.e. is not a parameter or standard monitoring
signal. These signals are presented with [Letter]. e.g. [FW]
MotorRegulatorStatus
[V]
Normal monitoring signal
[P]
Normal parameter in application.
[FW]
Firmware signal, Can be monitored with 9000xDrive
when signal type is selected Firmware
[A]
Application signal, can be monitored with 9000xDrive
when signal type is selected Application.
[R]
Reference type parameter on keypad.
[F]
Function. Signal is received as a output of function.
[DI]
Digital input signal.
3.1 Monitoring values
The monitoring values are the actual values of parameters
and signals as well as statuses and measurements.
otee:
N
for DriveSynch Systems:
In a DriveSynch system, only Master drive monitoring
signals are reliable.
Only directly measured values are reliable in follower units.
Even the Output Frequency of DriveSynch follower is not
directly observed and thus may not show actual output
frequency that is controlled by DriveSynch Master Drive.
Table 1 . Monitoring values
Code
Parameter
Unit
Form
ID
Description
V7.1
Output frequency
Hz
#,##
1
Output frequency to motor
V7.2
Frequency reference
Hz
#,##
25
Frequency reference to motor control
V7.3
Motor speed
rpm
#
2
Motor speed in rpm
V7.4
Motor current
A
Varies
3
1 s linear filtering
V7.5
Motor torque
%
#,#
4
In % of Motor nominal torque
V7.6
Motor power
%
#,#
5
V7.7
Motor voltage
V
#,#
6
Calculated motor voltage
V7.8
DC link voltage
V
#
7
Measured DC voltage, filtered.
V7.9
Unit temperature
°C
#
8
Heatsink temperature
V7.10
Motor temperature
%
#
9
Calculated motor temperature, trip 105 %
V7.11
Analog input 1
%
#,##
13
AI1, unfiltered.
V7.12
Analog input 2
%
#,##
14
AI2, unfiltered.
V7.13
Analog input 3
%
#,##
27
AI3, unfiltered.
V7.14
Analog input 4
%
#,##
28
AI4, unfiltered.
V7.15
Analog out 1
%
#,##
26
AO1
V7.16
Analog out 2
%
#,##
31
AO2
V7.17
Analog out 3
%
#,##
32
AO3
V7.18
Analog out 4
%
#,##
1526
V7.19
DIN1, DIN2, DIN3
15
Digital input statuses
V7.20
DIN4, DIN5, DIN6
16
Digital input statuses
V7.21
Power reference
%
#,#
1700
Used power reference
V7.22
PT-100 Temperature
Cº
#,#
42
Highest temperature of OPTB8 board. 4 s filtering.
V7.23
Motor KW
KW
1692
Motor instant KW
G7.24
Multimonitoring items
Displays three selectable monitoring values