251
5. Parameter Description
Eaton Electric General Inverters DF1 Series
UMXXXXXXXXE February 2020 www.eaton.com
Group
Parameter
Number
Name
Setting Range
Factory
Value
User
settings
14-19
P.617
Curling radius filtering time
0~1000ms
0ms
14-20
P.618
Current value of curling radius 0~10000mm
0mm
14-21
P.619
Number of pulses each turn
1~60000
1
14-22
P.620
Number of turns each layer
1~10000
1
14-23
P.621
Material thickness setting
source
0: The material thickness is set by the parameter 14-24
(P.622)~14-27 (P.625).
0
1: The material thickness is set by the analog value.
14-24
P.622
Material thickness 0
0.01~100.00mm
0.01mm
14-25
P.623
Material thickness 1
0.01~100.00mm
0.01mm
14-26
P.624
Material thickness 2
0.01~100.00mm
0.01mm
14-27
P.625
Material thickness 3
0.01~100.00mm
0.01mm
14-28
P.626
Maximum thickness
0.01~100.00mm
1.00mm
14-29
P.627
Line speed inputsource
0: No line speed input.
0
1: The analog value or pulse input
2: The communication setting.
14-30
P.628
Maximum line speed
0.1~6500.0m/min
1000.0m/
min
14-31
P.629
Minimum line speed for
calculation R
0.1~6500.0m/min
200.0m/
min
14-32
P.630
Actual line speed
0~6500.0m/min
0.0m/min
14-33
P.633
Mechanical inertia
compensation coefficient
0~65535
0
14-34
P.634
Material density
0~60000kg/ m
3
0kg/ m
3
14-35
P.635
Material width
0~60000mm
0mm
14-36
P.636
Fiction compensation coef-
ficient
0~50.0%
0.0%
14-37
P.637
Material supplyinterrupt auto
detection function
0: Material supply interrupt auto detection is inactive.
0
1: Material supply interrupt auto detection function 1
2: Material supply interrupt auto detection function 2
3: Material supply interrupt auto detection function 3
14-38
P.638
Auto detection minimum line
speed
0.1~6500.0m/min
200.0m/
mn
14-39
P.639
Auto detection error range
0.1~100.0%
10.0%
14-40
P.640
Auto detection judgment
delay
0.1~60.0s
2.0s
14-41
P.645
Pre-drive speed gain
-50.0%~50.0%
0.0%
14-42
P.646
Pre-drive torque increase
-50.0%~50.0%
0.0%
14-43
P.647
Pre-drive torque delay time
0~65535ms
0ms
14-44
P.656
Line speed setting source
0: The line speed setting is invalid.
0
1: The line speed is obtained by analog value or pulse input.
2: The line speed is obtained by communication mode.
14-45
P.657
Line speed setting
0~6500.0m/min
0.0m/min
14-46
P.658
Tension closed-loop limite
amplitude of benchmark
0: amplitude limitingis based on the motor rated power
0
1: amplitude limitingis based on system real-time line speed
14-47
P.659
Tension in closed-loop limite
amplitude of the bias
0.0%~100.0%
0.0%